Resolved Issues: 21.2R1
Interfaces
- On NFX250 devices, a VNF interface is not brought down when the VNF interface is mapped to an already link down or disabled peer physical interface. PR1555193
Performance Modes
Platform and Infrastructure
- RPD core file is generated when the device reboots and daemon restarts. Daemon recovers and there is no service impact on routing protocol usage. PR1567043
- On NFX350 devices and the SRX5000 line of devices with SPC3 card, the DPD Gateway failover feature is not supported. PR1564715
- The l2cpd core files might be seen on reboot. PR1561235
- On NFX150 devices, when J-Flow v5 is configured and the J-Flow v5 server is reachable through an IPsec tunnel, and the MTU size of this IPsec tunnel is configured as 1500, the J-Flow packets are not generated on NFX Series devices. As a workaround, use J-Flow v9 or IPFIX version, instead of J-Flow v5, to enable the J-Flow functionality on NFX Series devices. PR1539964
- You can transfer file from USB to hypervisor by enabling the usb-pass-through functionality. PR1535220
- On NFX150, NFX250 NextGen, and NFX350 devices, the
EmulatorPin CPUSet
option does not get configured, which might result in vCPU running on a higher level up to 100%. PR1540564 - The DSL SFP firmware cannot finish upgrade successfully through vmhost reboot. PR1547540