SCADA: TRI Coil Quantity Handling Denial of Service

This signature detects attempts to exploit a known vulnerability against SCADA Modbus Tri device. A successful attack can lead to denial of service.

Extended Description

Triangle Research International (aka Tri) Nano-10 PLC devices with firmware before r81 use an incorrect algorithm for bounds checking of data in Modbus/TCP packets, which allows remote attackers to cause a denial of service (networking outage) via a crafted packet to TCP port 502.

Short Name
SCADA:MODBUS:TRI-COIL-DOS
Severity
Major
Recommended
False
Recommended Action
Drop
Category
SCADA
Keywords
CVE-2013-2784 Coil Denial Handling Quantity Service TRI of
Release Date
07/23/2014
Supported Platforms

srx-branch-12.3

srx-19.3

srx-branch-19.3

vsrx3bsd-19.2

srx-branch-19.4

vsrx-19.4

mx-12.3

mx-19.4

vmx-19.4

mx-19.3

vsrx3bsd-19.4

srx-19.4

vsrx-12.3

vmx-19.3

vsrx-19.2

srx-12.3

Sigpack Version
3761
Port
TCP/502
False Positive
Unknown
CVSS Score

7.8