SCADA: DaqFactory HMI NETB Request Overflow

This signature detects attempts to exploit a known vulnerability in the DaqFactory HMI. A successful attack can lead to a buffer overflow and arbitrary remote code execution within the context of the server.

Extended Description

AzeoTech DAQFactory is prone to a buffer-overflow vulnerability because it fails to perform adequate boundary checks on user-supplied data. Attackers may leverage this issue to execute arbitrary code in the context of the application. Failed attacks will cause denial-of-service conditions. DAQFactory 5.85 build 1853 is vulnerable; other versions may also be affected.

Affected Products

Azeotech daqfactory

Short Name
SCADA:DEQFACTORY-NETB
Severity
Major
Recommended
False
Recommended Action
Drop
Category
SCADA
Keywords
CVE-2011-3492 DaqFactory HMI NETB Overflow Request bid:49606
Release Date
02/13/2012
Supported Platforms

srx-branch-12.3

srx-19.3

srx-branch-19.3

vsrx3bsd-19.2

srx-branch-19.4

vsrx-19.4

mx-12.3

mx-19.4

vmx-19.4

mx-19.3

vsrx3bsd-19.4

srx-19.4

vsrx-12.3

vmx-19.3

vsrx-19.2

srx-12.3

Sigpack Version
3336
Port
udp/20034
False Positive
Unknown
Vendors

Azeotech

CVSS Score

10.0

Found a potential security threat?