HTTP: Netgear ProSAFE NMS300 SettingConfigController Command Injection

This signature detects attempts to exploit a known vulnerability against Netgear ProSAFE NMS300. A successful attack can lead to arbitrary code execution.

Extended Description

This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System 1.6.0.26. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the SettingConfigController class. When parsing the fileName parameter, the process does not properly validate a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-12121.

Affected Products

Netgear prosafe_network_management_system

Short Name
HTTP:CTS:NETGEAR-PROSAFE-CMDINJ
Severity
Critical
Recommended
False
Recommended Action
Drop
Category
HTTP
Keywords
CVE-2021-27273 Command Injection NMS300 Netgear ProSAFE SettingConfigController
Release Date
04/19/2021
Supported Platforms

srx-branch-12.3

srx-19.3

srx-branch-19.3

vsrx3bsd-19.2

srx-branch-19.4

vsrx-19.4

mx-12.3

mx-19.4

vmx-19.4

mx-19.3

vsrx3bsd-19.4

srx-19.4

vsrx-12.3

vmx-19.3

vsrx-19.2

srx-12.3

Sigpack Version
3375
False Positive
Unknown
Vendors

Netgear

CVSS Score

9.0

Found a potential security threat?