Defining Alarm Thresholds for Battery Voltage Sensors
To configure SNMP chassis alarm thresholds for battery voltage sensors:
Set the editing level for the CLI to expert.
user@host> set cli level expertFrom configuration mode, access the configuration statement that defines the thresholds for battery voltage sensors.
[edit]user@host# edit snmp monitor chassis-alarm battery-voltage(Optional) Specify the lower threshold for the minor alarm. For example:
[edit snmp monitor chassis-alarm battery-voltage]user@host# set below-minor 3024(Optional) Specify the lower threshold for the major alarm. For example:
[edit snmp monitor chassis-alarm battery-voltage]user@host# set below-major 3008(Optional) Specify the lower threshold for the critical alarm. For example:
[edit snmp monitor chassis-alarm battery-voltage]user@host# set below-critical 2992(Optional) Specify the upper threshold for the minor alarm. For example:
[edit snmp monitor chassis-alarm battery-voltage]user@host# set over-minor 3744(Optional) Specify the upper threshold for the major alarm. For example:
[edit snmp monitor chassis-alarm battery-voltage]user@host# set over-major 3760(Optional) Specify the upper threshold for the critical alarm. For example:
[edit snmp monitor chassis-alarm battery-voltage]user@host# set over-critical 3776