Navigation
Table of Contents
Guide That Contains This Content
[+] Expand All
[-] Collapse All
Related Documentation
Monitoring Sensor Data Repository Information Using the IPMI on a Local Chassis (SRC CLI)
Purpose
Display IPMI Sensor Data Repository readings and status on the local C Series Controller.
![]() | Note: The show ipmi sdr command is not supported, if the SRC software is deployed as a virtual machine. |
Action
To display Sensor Data Repository information using IPMI:
user@host>show ipmi sdr CPU0 below Tmax | 53 degrees C | ok CPU1 below Tmax | disabled | ns DIMM0 Area(RT3) | 32 degrees C | ok PCI Area(RT2) | 39 degrees C | ok CPU0 VCORE. | 0.91 Volts | ok CPU1 VCORE | disabled | ns 3.3V | 3.38 Volts | ok +12V | 11.90 Volts | ok VBAT | 3.30 Volts | ok 5V | 4.92 Volts | ok Sys.2(CPU 0) | 3330 RPM | ok Sys.3(Front 1) | 3420 RPM | ok Sys.4(Front 2) | 3420 RPM | ok PS1 Present | 0x02 | ok PS1 PG | 0x01 | ok OTP1 | 0x01 | ok PS1 FAN | 0x01 | ok PS2 Present | 0x02 | ok PS2 PG | 0x01 | ok OTP2 | 0x01 | ok PS2 FAN | 0x01 | ok