[Contents] [Prev] [Next] [Report an Error]

cOC12/STM4 Multimode Without APS/MSP Redundancy Module Combination

Line module label cOCx/STMx F0
I/O module label cOC12 STM4 F0 I/O
MULTI MODE
Number of I/O ports
  • 1
Software release
  • First supported: 2.2.0
  • Final supported: N/A
Description
  • 130 W
  • OC12/STM4 channelized to DS3, DS1, E1, and DS0
Type
  • ASIC
Capability
  • OC12/STM4
  • OC3/STM1
  • DS3, DS1
  • T1, E1
  • DS0
  • HDLC framing
Software features
  • See Channelized OCx/STMx Modules for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
  • ERX-7xx models
  • ERX-14xx models
  • ERX-310 router
SRP module compatibility
  • SRP-5G+
  • SRP-10G
  • SRP-40G
  • SRP-40G PLUS
  • SRP-SE10G
Module redundancy support
  • 1:N redundancy
  • NOTE: Line module redundancy is not supported on the ERX-310 router.
Cables and connectors
  • SC full duplex connector
  • Tx power:
    • min: –19 dBm
    • max: –14 dBm
  • Center wavelength: 1310 nm
  • Rx input power:
    • min: –30 dBm
    • max: –14 dBm
  • Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB
  • See E-series Hardware Guide, Chapter 6, Cabling E-series Routers for more information.
LEDs
Alarms, errors, and events
  • See Monitoring Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 5, Configuring Channelized OCx/STMx Interfaces.