OC3/STM1 ATM Multimode Without APS/MSP Redundancy Module Combination
(128 MB)
This module combination is no longer supported
because the line module has reached end-of-life. However, the I/O
module is still supported.
Line module label | OCx/STMx ATM or OCx/STMx
/DS3-ATM |
I/O module label | OC3-4 I/O MULTI MODE |
Number of I/O ports | |
Software release | - First supported: 2.0.0
- Final supported: 5.2.x
|
Description | - 130 W
- Unchannelized, concatenated OC3/STM1 for ATM
|
Type | |
Capability | |
Software features | - See ERX Module Guide, Appendix A, Module Protocol
Support for information about the layer 2 and layer 3 protocols
and applications that this module combination supports.
|
Model compatibility | - ERX7xx models
- ERX14xx models
- ERX310 router
|
SRP module compatibility | - SRP-5G+
- SRP-10G
- SRP-40G
- SRP-40G PLUS
- SRP-SE10G
|
Module redundancy support | - 1:N redundancy
- NOTE: Line module redundancy
is not supported on the ERX310 router.
|
Cables and connectors | - SC full duplex connector
- Tx power:
- Center wavelength: 1310 nm
- Rx input power:
- min: –30 dBm
- max: –14 dBm
- Rated for 2 km (1.2 miles) over 62.5-micron core cable
with an optical loss of 0–9 dB or 50-micron core cable with
an optical loss of 7 dB
- See ERX Hardware Guide, Chapter 5, Cabling
ERX Routers for more information.
|
LEDs | - See ERX Module Guide, Appendix B, Module LEDs.
|