Chassis, fully configured |
|
Chassis with single power supply Chassis with dual power supply Chassis with single power supply, fully configured Chassis with dual power supply, fully configured |
|
|
5.2 (H) x 19 (W) x 16 (D) inches; 13.21 x 48.26 x 40.64 cm |
Environmental Requirements Ambient operating temperature Ambient operating humidity Ambient storage temperature |
NEBS GR-63-CORE compliant Long term: 41° to 104° F (5° to 40° C) Short term: 23° to 122° F (-5° to 50° C) Long term: 5% to 85% (noncondensing) Short term: 5% to 95% (noncondensing) -40° to 158° F (-40° to +70° C), 95% relative humidity 5% to 95% (noncondensing) |
|
500 W, 1706 BTU/hour maximum |
|
- 3 feet (90 cm) behind router or rack
- Do not block air vents on sides of the router.
- Do not place equipment that exhausts hot air to left on the right of the router.
- Be aware that router exhausts hot air from its left side.
|
|
|
|
|
|
|
|
- Not yet available for the ERX-310 router
|
Safety Agency Certification |
- AS/NZS 3260:1993, Safety of Information Technology Equipment Including Electrical Business Equipment
- CAN/CSA C22.2, No. 60950-00, 3rd Edition, Safety of Information Technology Equipment
- EN60825-1, Safety of Laser Products - Part 1: Equipment Class, Requirements, and User's Guide (2001)
- EN60950:2000, 3rd Edition, Safety of Information Technology Equipment
- IEC 60950-1(2001-10) Ed. 1.0 Information technology equipment - Safety - Part 1: General requirements
- Low Voltage Directive (73/23/EEC)
- UL 60950, 3rd Edition, Safety of Information Technology Equipment
|
Electromagnetic Emissions Agency Certification |
- AS/NZS 3548:1995 (CISPR 22 Class A)
- EMC Directive (89/336/EEC)
- EN55022 Class A (CISPR-22 Class A)
- EN55024, Annex C for WAN Equipment Performance Criteria A, B, and C
- ETSI 300-386, Telecommunication Network Equipment; ElectroMagnetic Compatibility (EMC) requirements
- FCC Part 15 Class A
- IECS-003 Issue 3 Class A
- VCCI (Voluntary Control Council for Interference by Information Technology Equipment)
|
Telecommunications Certification |
- ACA TS 016-1997
- CTR13 - Commission Decision of 9 July 1997 on a common technical regulation for attachment requirements for terminal equipment interface for connection to 2048 kbit/s digital structured ONP leased lines: 97/521/EC - OJ No. L215 Vol. 40, August 1997
- CTR24 - Commission Decision of 9 September 1997 on a common technical regulation for attachment requirements for terminal equipment interface for connection to 34 Mbit/s digital unstructured and structured leased lines: 97/639/EC - OJ No. L271 Vol. 40, 3 October 1997
- FCC PART 68
- IECS-003 Issue 3 Class A
- PD7024 - Essential requirements for terminal equipment intended for connection to unstructured digital leased circuits of the public telecommunications network using a CCITT recommendation G,703 interface at a rate of 2048 kbit/s with a 75 ohm unbalanced presentation, 1994
- RTTE Directive (1999/5/EEC)
|