100-Gigabit Ethernet PIC with CFP (PTX Series)

Software Release
PTX3000: Junos OS Release 13.2R2 and later
PTX5000:
Note:PTX5000 does not support Junos OS Release 13.1.
Junos OS Release 12.1X48 and later 12.1X48 releases
Junos OS Release 12.3 and later 12.3 releases
Junos OS Release 13.2 and later releases
PTX5000 does not support Junos OS Releases 12.1, 12.2, or 13.1.
Hardware Features
Two 100-Gigabit Ethernet CFP ports
Model number P1-PTX-2-100GE-CFP
Name in the CLI:
2x 100GE CFP
Power requirements: 1.6 A @ –48 V (75 W)
Large maximum transmission units (MTUs):
Junos OS Release 12.1X48: up to 9192 bytes
Junos OS Release 12.1X48R2 and later 12.1X48 releases: up to 9500 bytes
Junos OS Release 12.3 and later 12.3 releases: up to 9500 bytes
Software Features
Table 1 shows the first supported release for each software feature.
Software Feature |
PTX3000 First Supported Junos OS Release |
PTX5000 First Supported Junos OS Release |
---|---|---|
Flexible-ethernet-services encapsulation |
13.2R2 |
12.1X48 12.3 13.2 |
Flexible VLAN tagging |
13.2R2 |
12.1X48 12.3 13.2 |
IFINFO / IFMON |
13.2R2 |
12.1X48 12.3 13.2 |
IEEE 802.1 ag OAM |
13.2R2 |
12.1X48 12.3 13.2 |
IEEE 802.3 ah OAM |
13.2R2 |
12.1X48 12.3 13.2 |
IEEE 802.3ad link aggregation |
13.2R2 |
12.1X48 12.3 13.2 |
Interrupt-driven link-down detection for MPLS FRR |
13.2R2 |
12.1X48 12.3 13.2 |
MAC accounting per logical interface for source addresses |
13.2R2 |
12.1X48 12.3 13.2 |
MAC filter per port for destination addresses and source addresses |
13.2R2 |
12.1X48 12.3 13.2 |
MAC filter per logical interface for source addresses |
13.2R2 |
12.1X48 12.3 13.2 |
SNMP |
13.2R2 |
12.1X48 12.3 13.2 |
Up to 8000 logical interfaces share across all ports on a single PFE |
13.2R2 |
12.1X48 12.3 13.2 |
Cables and Connectors
100GBASE-ER4 (model number: CFP-100GBASE-ER4)
Duplex LC connector (RX and TX)
Junos OS Release 12.1X48R4 and later 12.1X48 releases
Junos OS Release 12.3 and later 12.3 releases
Junos OS Release 13.2 and later releases
100GBASE-ER4 (model number: CFP-GEN2-CGE-ER4 and part number: 740-049763)
Duplex LC connector (RX and TX)
Junos OS Release 12.3R5 and later 12.3 releases
Junos OS Release 13.2R3 and later 13.2 releases
Junos OS Release 13.3 and later releases
Note:The “GEN2” optics have been redesigned with newer versions of internal components for reduced power consumption.
100GBASE-LR4 (model number: CFP-100GBASE-LR4)
Duplex SC connector (RX and TX)
Junos OS Release 12.1X48 and later 12.1X48 releases
Junos OS Release 12.3 and later 12.3 releases
Junos OS Release 13.2 and later releases
100GBASE-LR4 (model number: CFP-GEN2-100GBASE-LR4 and part number: 740-047682)
Duplex LC connector (RX and TX)
Junos OS Release 12.3R5 and later 12.3 releases
Junos OS Release 13.2R3 and later 13.2 releases
Junos OS Release 13.3 and later releases
Note:The “GEN2” optics have been redesigned with newer versions of internal components for reduced power consumption.
100GBASE-SR10 (model number: CFP-100GBASE-SR10)
24-fiber MPO connectors
Junos OS Release 12.1X48R3 and later 12.1X48 releases
Junos OS Release 12.3 and later 12.3 releases
Junos OS Release 13.2 and later releases
100GBASE-ZR (model number: CFP-100GBASE-ZR)
Duplex LC connector (RX and TX)
Supported in Junos OS Release 13.3R6, 14.1R4, 14.2R3, and 15.1R1 and later
Provides advanced dual polarization-quadrature phase shift keying (DP-QPSK) coherent digital signal processing (DSP) and forward error correction (FEC)-enabled robust tolerance to optical impairments and supports 80 km reach over single mode fiber
The transceiver is not specified as part of IEEE 802.3 but is built according to Juniper Networks specifications.
Optical interface specifications—see 100-Gigabit Ethernet 100GBASE-R Optical Interface Specifications
LEDs
The STATUS LED is located above the ONLINE OFFLINE button. The LINK and ACT LEDs are located next to each port. Table 2 describes the functions of these LEDs.
Label |
Color |
State |
Description |
---|---|---|---|
STATUS |
Green |
On steadily |
PIC is online with no alarms or failures. |
Yellow |
On steadily |
PIC is initializing. |
|
Red |
On steadily |
PIC is online but has errors or alarms. |
|
– |
Off |
PIC is offline or not enabled. |
|
LINK for each port: |
Green |
On steadily |
Port is online with no alarms or failures, and the link is up. |
Red |
On steadily |
Port is on but the link is down, and the port has detected a failure with alarms. |
|
– |
Off |
Port is off or not enabled. |
|
ACT for each port |
Green |
Flashing |
Activity detected. Port is sending or receiving packets. |
– |
Off |
No packet activity detected on the port. |
Alarms, Errors, and Events
Alarm indication signal (AIS)
Laser bias current high/low alarms and warnings
Laser Rx power high/low alarms and warnings
Module not ready alarm
Module power down alarm
Module temperature high/low alarms and warnings
Rx CDR loss of lock alarm
Rx loss of signal alarm
Rx not ready alarm
Tx CDR loss of lock alarm
Tx data not ready alarm
Tx laser fault alarm
Tx not ready alarm