Removing an AC Power Supply

The power supplies are located at the rear of the chassis. Each AC power supply weighs approximately 5.0 lb (2.3 kg).

Caution: Do not leave a power supply slot empty for more than 30 minutes while the services gateway is operational. For proper airflow, the power supply must remain in the chassis, or a blank panel must be used in an empty slot.

Note: After powering off a power supply, wait at least 60 seconds before turning it back on.

To remove an AC power supply (see Figure 2):

  1. Switch off the dedicated facility circuit breaker for the power supply, and remove the power cord from the AC power source. Follow the ESD and disconnection instructions for your site.
  2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see Preventing Electrostatic Discharge Damage.
  3. Move the AC switch next to the appliance inlet on the power supply to the off position (O).
  4. Unscrew the captive screws on the bottom edge of the power supply.
  5. Remove the power cord from the power supply.
  6. Pull the power supply straight out of the chassis.

Figure 2: Removing an AC Power Supply

Image g004236.gif


[ Contents] [ Prev] [ Next] [ Report an Error]