Configuring RPM Receiver Servers
The RPM TCP and UDP probes are proprietary to Juniper Networks and require a receiver
to receive the probes. To configure a server to receive the probes, include the
probe-server statement at the [edit services
rpm] hierarchy
level for Junos OS
or the [edit services monitoring rpm] hierarchy level for Junos OS
Evolved:
[edit services rpm] probe-server { tcp { destination-interface interface-name; port number; } udp { port number; } }
The port number specified for the UDP and TCP server can be 7 or
from 49160 through 65535.
The destination-interface statement is not supported on PTX
Series Packet Transport
routers, or
for devices running Junos OS Evolved.
When
you configure either probe-type udp-ping or probe-type
udp-ping-timestamp along with the
one-way-hardware-timestamp command, the value for the
destination-port can be only 7. A constraint check prevents you
for configuring any other value for the destination port in this case.