show security flow status
Syntax
show security flow status
Description
Display the flow processing modes and logging status.
Required Privilege Level
view
Output Fields
Table 1 lists the output fields for the
show security flow status command. Output fields are listed in the
approximate order in which they appear.
|
Field Name |
Field Description |
|---|---|
|
Flow forwarding mode |
Flow processing mode.
|
|
Flow trace status |
Flow logging status.
|
|
flow session distribution |
SPU load distribution mode.
GTP-U distribution
|
|
Flow packet ordering |
packet-ordering mode.
|
|
Flow ipsec performance acceleration |
IPsec VPN performance acceleration status. |
|
Flow power mode IPsec |
Flow PowerMode IPsec status. |
|
Flow Enhanced Service Mode |
Flow Enhanced Service Mode status
|
|
Flow gre performance acceleration |
GRE performance acceleration status. |
Sample Output
- show security flow status
- show security flow status (IPsec Performance Acceleration)
- show security flow status (for hash-based datapath forwarding using SRX5K-MPC3-40G10G (IOC3) and SRX5K-MPC3-100G10G (IOC3)
- show security flow status (SRX5400, SRX5600, SRX5600, and vSRX Virtual Firewall)
- show security flow status (Tap mode enabled with IP-IP or GRE tunnel inspection on SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, and SRX4200)
- show security flow status (Enhanced Service Mode enabled on vSRX Virtual Firewall 3.0)
- show security flow status (GRE Performance Acceleration)
- show security flow status (PowerMode IPsec QAT)
show security flow status
user@host> show security flow status
Flow forwarding mode:
Inet forwarding mode: flow based
Inet6 forwarding mode: flow based
MPLS forwarding mode: drop
ISO forwarding mode: drop
Tap mode: disabled (default)
Enhanced services mode: Disabled
Flow trace status
Flow tracing status: on
Flow tracing options: all
Flow tracing level: detail
Flow trace root-override status: on
Flow session distribution
Distribution mode: Hash-based
GTP-U distribution: Disabled
Flow ipsec performance acceleration: off
Flow gre performance acceleration: off
Flow packet ordering
Ordering mode: Hardware
Flow power mode IPsec: Disabled
Flow power mode IPsec QAT: Disabled
Fat core group status: off
Flow inline fpga crypto: Disablednode1:
--------------------------------------------------------------------------
Flow forwarding mode:
Inet forwarding mode: flow based
Inet6 forwarding mode: flow based
MPLS forwarding mode: drop
ISO forwarding mode: drop
Tap mode: disabled (default)
Flow trace status
Flow tracing status: off
Flow session distribution
Distribution mode: RR-based
GTP-U distribution: Disabled
SCTP distribution: Enabled
Flow ipsec performance acceleration: off
Flow gre performance acceleration: off
Flow packet ordering
Ordering mode: Hardware
Flow power mode: Enabled
Flow power mode IPsec: Enabled
Flow power mode IPsec QAT: Disabled
Fat core group status: off
Flow inline fpga crypto: DisabledLogical system or tenant system user output.
Flow trace status Flow tracing status: on Flow tracing options: all Flow tracing level: detail Flow trace root-override status: on
user@host> show security flow status
Flow forwarding mode:
Inet forwarding mode: flow based
Inet6 forwarding mode: drop
MPLS forwarding mode: drop
ISO forwarding mode: drop
TAP mode: enabled
Flow trace status
Flow tracing status: off
Flow session distribution
Distribution mode: RR-based
GTP-U distribution: Enabled Flow packet ordering
Ordering mode: Software (reboot needed to change to software)
Flow power mode IPsec: Enabledshow security flow status (IPsec Performance Acceleration)
user@host> show security flow status
node0:
--------------------------------------------------------------------------
Flow forwarding mode:
Inet forwarding mode: flow based
Inet6 forwarding mode: flow based
MPLS forwarding mode: drop
ISO forwarding mode: drop
Tap mode: disabled (default)
Flow trace status
Flow tracing status: off
Flow session distribution
Distribution mode: Hash-based
GTP-U distribution: Disabled
Flow ipsec performance acceleration: off
Flow packet ordering
Ordering mode: Hardware
Flow power mode IPsec: Enabled
Fat core group status: on
node1:
--------------------------------------------------------------------------
Flow forwarding mode:
Inet forwarding mode: flow based
Inet6 forwarding mode: flow based
MPLS forwarding mode: drop
ISO forwarding mode: drop
Tap mode: disabled (default)
Flow trace status
Flow tracing status: off
Flow session distribution
Distribution mode: Hash-based
GTP-U distribution: Disabled
Flow ipsec performance acceleration: off
Flow packet ordering
Ordering mode: Hardware
Flow power mode IPsec: Enabled
Fat core group status: on
show security flow status (for hash-based datapath forwarding using SRX5K-MPC3-40G10G (IOC3) and SRX5K-MPC3-100G10G (IOC3)
user@host> show security flow status
Flow forwarding mode:
Inet forwarding mode: flow based
Inet6 forwarding mode: flow based
MPLS forwarding mode: drop
ISO forwarding mode: drop
Tap mode: disabled (default)
Flow trace status
Flow tracing status: off
Flow session distribution
Distribution mode: Hash-based
GTP-U distribution: Disabled
Flow ipsec performance acceleration: off
Flow packet ordering
Ordering mode: Hardware
Flow power mode IPsec: Disabled
Fat core group status: on
show security flow status (SRX5400, SRX5600, SRX5600, and vSRX Virtual Firewall)
user@host> show security flow status Flow forwarding mode: Inet forwarding mode: flow based Inet6 forwarding mode: flow based MPLS forwarding mode: drop ISO forwarding mode: drop Tap mode: enabled, inspect ipip …
show security flow status (Tap mode enabled with IP-IP or GRE tunnel inspection on SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, and SRX4200)
user@host> show security flow status
Flow forwarding mode:
Inet forwarding mode: flow based
….
Flow packet ordering
Ordering mode: Hardware
Flow power mode IPsec: Disabled
Flow Enhanced Service Mode: Enabled
…show security flow status (Enhanced Service Mode enabled on vSRX Virtual Firewall 3.0)
user@host> show security flow status
Flow forwarding mode:
Inet forwarding mode: flow based
Inet6 forwarding mode: flow based
MPLS forwarding mode: drop
ISO forwarding mode: drop
Tap mode: disabled (default)
Flow trace status
Flow tracing status: off
Flow session distribution
Distribution mode: Hash-based
GTP-U distribution: Disabled
Flow ipsec performance acceleration: off
Flow packet ordering
Ordering mode: Hardware
Flow power mode IPsec: Disabled
Flow power mode IPsec QAT: Enabled
Fat core group status: off
Flow inline fpga crypto: Disabled
show security flow status (GRE Performance Acceleration)
user@host> show security flow status Flow forwarding mode: Inet forwarding mode: flow based Inet6 forwarding mode: drop MPLS forwarding mode: drop ISO forwarding mode: drop TAP mode: enabled Flow trace status Flow tracing status: off Flow session distribution Distribution mode: RR-based GTP-U distribution: Enabled Flow packet ordering Ordering mode: Software (reboot needed to change to software) Flow power mode IPsec: Disabled Flow gre performance acceleration: on
show security flow status (PowerMode)
user@host> show security flow status
node0:
--------------------------------------------------------------------------
Flow forwarding mode:
Inet forwarding mode: flow based
Inet6 forwarding mode: flow based
MPLS forwarding mode: drop
ISO forwarding mode: drop
Tap mode: disabled (default)
Flow trace status
Flow tracing status: off
Flow session distribution
Distribution mode: Hash-based
GTP-U distribution: Disabled
SCTP distribution: Enabled
Flow ipsec performance acceleration: off
Flow gre performance acceleration: off
Flow packet ordering
Ordering mode: Hardware
Flow power mode: Enabled
Flow power mode IPsec: Enabled
Flow power mode IPsec QAT: Disabled
Fat core group status: on
Flow inline fpga crypto: Disabledshow security flow status (PowerMode IPsec QAT)
show security flow status (MX-SPC3 services card)
user@host> show security flow status
Flow forwarding mode:
Inet forwarding mode: flow based
Inet6 forwarding mode: flow based
MPLS forwarding mode: drop
ISO forwarding mode: drop
Tap mode: disabled (default)
Flow trace status
Flow tracing status: off
Flow session distribution
Distribution mode: Hash-based
GTP-U distribution: Disabled
Flow ipsec performance acceleration: off
Flow packet ordering
Ordering mode: Hardware
Flow power mode IPsec: Enabled
Fat core group status: on
Release Information
Command introduced in Junos OS Release 10.2; session distribution mode option added in Junos OS Release 12.1X44-D10; enhanced route scaling mode option added in Junos OS Release 12.1X45-D10. GTP-U distribution option added in Junos OS Release 15.1X49-D40.
Starting in Junos OS Release 15.1X49-D10 and Junos OS Release 17.3R1, SRX5K-MPC3-100G10G (IOC3) and SRX5K-MPC3-40G10G (IOC3) are introduced for SRX5400, SRX5600, and SRX5800 devices that perform hash-based data path packet forwarding to interconnect with all existing IOC and SPC cards using the XL chip (packet-processing chip).
The IOC3 XL chip uses a hash-based method to distribute ingress traffic to a pool of SPUs by default. Selection of hash keys depends on application protocols.
Starting in Junos OS Release 18.3R1, flow PowerMode IPsec support is introduced on vSRX Virtual Firewall instances.
Starting in Junos OS Release 18.4R1, flow PowerMode IPsec support is introduced on SRX4100 and SRX 4200 devices.
Starting in Junos OS Release 18.2R2, flow PowerMode IPsec support is introduced on SRX5400, SRX5600, and SRX5800 devices.
Starting in Junos OS Release 19.1R1, flow PowerMode IPsec support is introduced on SRX4600 devices.
Starting in Junos OS Release 19.4R1, symmetric fat tunnel support is introduced on SRX5400, SRX5600, SRX5800, and vSRX Virtual Firewall instances.
Starting in Junos OS Release 20.3R1, Enhanced Service Mode is supported on
vSRX Virtual Firewall 3.0. In this mode of service vSRX Virtual Firewall 3.0 can support upto 128K L7 service sessions with
increased service memory. By default, ESM is disabled and the vSRX Virtual Firewall 3.0 is in basic firewall
mode. You can enable ESM using the set security forwarding-process
enhanced-services-mode command. After enabling this mode, you need to reboot the
instance. When you enable this configuration, you will receive a warning message
warning: You have changed enhanced services mode. You must reboot the system
for your change to take effect. If you have deployed a cluster, be sure to reboot all
nodes.
Starting in Junos OS Release 20.4R1, the jexec,
minimal, and root-override support is introduced on
SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 line of devices, and vSRX Virtual Firewall. The options
route, session-scan, and tunnel at
[edit security flow traceoptions flag] hierarchy are configured only by
root user.
Starting in Junos OS Release 21.1R1, we support the PMI and GRE acceleration solutions to improve the software-defined WAN (SD-WAN) performance.
For PMI solution, include the
power-mode-ipsec and gre-performance-acceleration
statements at the [edit security flow] hierarchy level. PMI
supports both IPsec and GRE. In this case, traffic flows through the PMI data path.
For GRE acceleration solution, include the
gre-performance-acceleration statement at the [edit security
flow] hierarchy level. By default,
gre-performance-acceleration is turned off. In this case, traffic flows
through the GRE acceleration data path.