show ethernet-switching layer2-protocol-tunneling vlan
Syntax
show ethernet-switching-layer2-protocol-tunneling vlan <vlan-name>
Description
Display information about Layer 2 protocol tunneling (L2PT) on VLANs that have been configured for L2PT.
Options
| none | Display information about L2PT for the VLANs on which you have configured L2PT. |
| vlan-name | (Optional) Display information about L2PT for the specified VLAN. |
Required Privilege Level
view
Output Fields
Table 1 lists the
output fields for the show ethernet-switching layer2-protocol-tunneling
vlan command. Output fields are listed in the approximate order
in which they appear.
Field Name |
Field Description |
|---|---|
VLAN |
Name of the VLAN on which L2PT has been configured. |
Protocol |
Name of a protocol for which L2PT has been enabled. Values are all, 802.1x, 802.3ah, cdp, e-lmi, gvrp, lacp, lldp, mmrp, mvrp, stp, vstp, and vtp. |
Drop Threshold |
Maximum number of Layer 2 PDUs of the specified protocol that can be received per second on the VLAN before the switch begins dropping the Layer 2 PDUs. |
Shutdown Threshold |
Maximum number of Layer 2 PDUs of the specified protocol that can be received per second on the VLAN before the interface is disabled. |
Sample Output
- show ethernet-switching layer2-protocol-tunneling vlan
- show ethernet-switching layer2-protocol-tunneling vlan v2
show ethernet-switching layer2-protocol-tunneling vlan
user@switch> show ethernet-switching layer2-protocol-tunneling vlan
Layer2 Protocol Tunneling VLAN information:
VLAN Protocol Drop Shutdown
Threshold Threshold
v1 mvrp 100 200
v2 cdp 0 0
v2 cdp 0 0
v2 gvrp 0 0
show ethernet-switching layer2-protocol-tunneling vlan v2
user@switch> show ethernet-switching layer2-protocol-tunneling vlan v2
Layer2 Protocol Tunneling VLAN information:
VLAN Protocol Drop Shutdown
Threshold Threshold
v2 cdp 0 0
v2 cdp 0 0
v2 gvrp 0 0
Release Information