show chassis high-availability information
Syntax
show chassis high-availability information
Description
Display details of the Multinode High Availability status on your security device including health status of the peer node.
Required Privilege Level
view
Output Fields
Table 1 lists
the output fields for the show chassis high-availability information command. Output fields are listed in the approximate order in which
they appear.
Field Name |
Field Description |
|---|---|
|
Node failure codes are:
|
|
|
|
|
HA Hardware Upgrade
Events |
Message on additional SPC3 installation status. |
|
|
|
|
|
|
Sample Output
- show chassis high-availability information
- show chassis high-availability information detail
- show chassis high-availability information (Junos OS 23.4R1)
show chassis high-availability information
user@host> show chassis high-availability information
Node failure codes:
HW Hardware monitoring LB Loopback monitoring
MB Mbuf monitoring SP SPU monitoring
CS Cold Sync monitoring SU Software Upgrade
Node Status: ONLINE
Local-id: 2
Local-IP: 10.22.0.2
HA Peer Information:
Peer Id: 1 IP address: 10.22.0.1 Interface: ge-0/0/2.0
Routing Instance: default
Encrypted: YES Conn State: DOWN
Cold Sync Status: IN PROGRESS
Services Redundancy Group: 0
Current State: ONLINE
Peer Information:
Peer Id: 1
SRG failure event codes:
BF BFD monitoring
IP IP monitoring
IF Interface monitoring
CP Control Plane monitoring
Services Redundancy Group: 1
Deployment Type: ROUTING
Status: ACTIVE
Activeness Priority: 1
Preemption: DISABLED
Process Packet In Backup State: NO
Control Plane State: READY
System Integrity Check: N/A
Failure Events: NONE
Peer Information:
Peer Id: 1
Status : BACKUP
Health Status: HEALTHY
Failover Readiness: READY
show chassis high-availability information detail
user@host> show chassis high-availability information detail
Node level Information:
Node Status: ONLINE
Local-id: 2
Local-IP: 10.22.0.2
HA Peer Information:
Peer-ID: 1 IP address: 10.22.0.1 Interface: ge-0/0/2.0
Routing Instance: default
Encrypted: YES Conn State: UP
Cold Sync Status: COMPLETE
Internal Interface: st0.16000
Internal Local-IP: 180.100.1.2
Internal Peer-IP: 180.100.1.1
Internal Routing-instance: __juniper_private1__
Packet Statistics:
Receive Error : 0 Send Error : 0
Packet-type Sent Received
SRG Status Msg 9 8
SRG Status Ack 8 7
Attribute Msg 3 2
Attribute Ack 2 2
HA Peer Conn events:
Dec 11 22:22:18.696 : HA Peer 180.100.1.1 BFD conn came up
Dec 11 22:22:25.269 : HA Peer 180.100.1.1 BFD conn went down
Dec 11 22:22:31.619 : HA Peer 180.100.1.1 BFD conn came up
Cold Synchronization:
Status:
Cold synchronization completed for: N/A
Cold synchronization failed for: N/A
Cold synchronization not known for: N/A
Current Monitoring Weight: 0
Progress:
CS Prereq 1 of 1 SPUs completed
1. if_state sync 1 SPUs completed
2. ha peer conn 1 SPUs completed
3. policy data sync 1 SPUs completed
4. cp ready 1 SPUs completed
5. VPN data sync 1 SPUs completed
6. IPID data sync 1 SPUs completed
7. All SPU ready 1 SPUs completed
8. AppID ready 1 SPUs completed
9. Tunnel Sess ready 1 SPUs completed
CS RTO sync 1 of 1 SPUs completed
CS Postreq 1 of 1 SPUs completed
Statistics:
Number of cold synchronization completed: 0
Number of cold synchronization failed: 0
Events:
Dec 11 22:22:23.870 : Cold sync for PFE is Post-req check in process
Dec 11 22:22:24.872 : Cold sync for PFE is Completed
Dec 11 22:22:37.293 : Cold sync for PFE is Post-req check in process
Dec 11 22:22:38.291 : Cold sync for PFE is Completed
SPU monitoring:
Status: Enabled
Current monitoring weight: 0
Statistics:
SPU up count: 1
NPC up count: 0
SPU down count: 0
NPC down count: 0
Chassis info processing error count: 0
Loopback Information:
PIC Name Loopback Nexthop Mbuf
-------------------------------------------------
Success Success Success
Hardware monitoring:
Status:
Activation status: Enabled
Ctrl Plane Hardware errors: 0
Data Plane Hardware errors: 0
SRGS Information:
Services Redundancy Group: 1
Deployment Type: ROUTING
Status: BACKUP
Activeness Priority: 1
Hold Timer: 1
Services: [ IPSEC ]
Process Packet In Backup State: NO
Control Plane State: READY
System Integrity Check: COMPLETE
Peer Information:
Failure Events: NONE
Peer Id: 1
Last Advertised HA Status: ACTIVE
Last Advertised Health Status: HEALTHY
Failover Readiness: N/A
Signal Route Info:
Active Signal Route:
IP: 10.39.1.1
Routing Instance: default
Status: NOT INSTALLED
Backup Signal Route:
IP: 10.39.1.2
Routing Instance: default
Status: INSTALLED
Split-brain Prevention Probe Info:
DST-IP: 10.111.0.1
SRC-IP: 10.11.0.1
Routing Instance: default
Status: NOT RUNNING
Result: N/A Reason: N/A
SRG State Change Events:
Dec 11 22:21:36.379 : SRG[1] state UNKNOWN -> HOLD, Reason: State machine start
Dec 11 22:23:28.889 : SRG[1] state HOLD -> ACTIVE, Reason: Peer state Backup adv received
Dec 11 22:23:31.152 : SRG[1] state ACTIVE -> BACKUP, Reason: HA state preemption
BFD Monitoring:
Status: UNKNOWN
SRC-IP: 10.5.0.1 DST-IP: 10.5.0.2
Routing Instance: default
Type: SINGLE-HOP
IFL Name: ge-0/0/3.0
State: INSTALLED
Interface Monitoring:
Status: UP
IF Name: ge-0/0/4 State: Up
IF Name: ge-0/0/3 State: Up
show chassis high-availability information (Junos OS 23.4R1)
user@host> show chassis high-availability information
Node failure codes:
HW Hardware monitoring LB Loopback monitoring
MB Mbuf monitoring SP SPU monitoring
CS Cold Sync monitoring SU Software Upgrade
Node Status: ONLINE
Local-id: 1
Local-IP: 10.22.0.1
Local Forwarding IP: 100.1.1.1
HA Peer Information:
Peer Id: 2 IP address: 10.22.0.2 Interface: ge-0/0/2.0
Routing Instance: default
Encrypted: YES Conn State: UP
Configured BFD Detection Time: 5 * 400ms
Cold Sync Status: COMPLETE
Peer Forwarding IP: 200.1.1.1 Interface: lo0.0
Peer ICD Conn State: UP
Services Redundancy Group: 0
Current State: ONLINE
Peer Information:
Peer Id: 2
SRG failure event codes:
BF BFD monitoring
IP IP monitoring
IF Interface monitoring
CP Control Plane monitoring
Services Redundancy Group: 1
Deployment Type: ROUTING
Status: ACTIVE
Activeness Priority: 200
Preemption: ENABLED
Process Packet In Backup State: NO
Control Plane State: READY
System Integrity Check: N/A
Failure Events: NONE
Peer Information:
Peer Id: 2
Status : BACKUP
Health Status: HEALTHY
Failover Readiness: READYRelease Information
Command introduced in Junos OS Release 20.4R1.