[ Contents] [ Prev] [ Next] [ Report an Error]

T1 PIC

Image g001387.gif

Software release
  • JUNOS 6.4 and later
Description
  • Four T1 ports
  • Power requirement: 0.08 A @ 48 V (3.7 W)
  • Supports clear channel T1 per port (1.544 Mbps per channel)
  • Supports attenuation up to –12 dBm
Hardware features
  • Per-port loop timing
  • Onboard DSU functionality for T1 connectivity
Software features
  • ESF and SF framing
  • B8ZS and AMI coding
  • ESF CSU counters, WRT impairments, and CRC checking
  • Local DS1 line loopback, remote line loopback
  • Configurable clock source—internal or loop
  • Encapsulations:
    • High-Level Data Link Control (HDLC)
    • Frame Relay
    • Circuit cross-connect (CCC)
    • Point-to-Point Protocol (PPP)
Cables and connectors
  • 100-ohm RJ-48 connector
LEDsOne tricolor per port:
  • Off—Not enabled
  • Green—Online with no alarms or failures
  • Amber—Online with alarms for remote failures
  • Red—Active with a local alarm; router has detected a failure
Alarms, errors, and events
  • Alarm indication signal (AIS)
  • Bipolar violations
  • Excessive zeros
  • Far-end block errors (FEBE, E-bit errors)
  • Loss of frame (LOF)
  • Loss of signal (LOS)
  • Yellow alarm bit (X-bit) disagreements