This section lists the issues fixed in WANDL IP/MPLSView Release 6.2.0.

  • When you log in as a non-WANDL user and select Web > Network Map, the Network Map opens the networks of WANDL users. [PR/1037260: This issue has been resolved.]
  • In the Device Change Tracking window, committing a change to a hostname fails with the following error message: “Could not commit changes to the hostname.” A similar commit failure occurs when you right-click a task in Task Manager and select Remove Nodes in Scheduled Tasks. [PR/1045988: This issue has been resolved.]
  • If Chinese characters are included in the export report from the Compliance Assessment Tool window, the exported CSV file contains unreadable code. [PR/1047953: This issue has been resolved.]
  • Adding a Martini VPN to the network does not work as expected, and sometimes generates a core error. [PR/1049512: This issue has been resolved.]
  • In the Event Map, the node does not change to the appropriate color for its severity level as expected when an event is received or when you clear all events. [PR/1051951: This issue has been resolved.]
  • When you right-click an event in Live Event View from the Event Browser, only those nodes associated with the selected event should be highlighted. Instead, nodes associated with previously selected events erroneously remain highlighted when you right-click subsequent events associated with different nodes. [PR/1053393: This issue has been resolved.]
  • The Tunnel Event Viewer displays incorrect status for the tunnel path. [PR/1053704: This issue has been resolved.]
  • The Event Browser randomly fails to display certain events as expected. [PR/1053835: This issue has been resolved.]
  • During a Schedule Live Network Collection task to collect configuration information from several devices in a single device profile, the operation fails because it cannot connect to the first device. When this occurs, the Schedule Live Network Collection task does not continue the collection on the other devices in the profile as expected, even though those devices are individually reachable. [PR/1062287: This issue has been resolved.]
  • The Report Server fails to install as expected. [PR/1063984: This issue has been resolved.]
  • SNMP statistics can sometimes display improperly when E Series routers are added to the network topology. [PR/1064332: This issue has been resolved.]
  • The installation files for the Application Server, Viewer Server, Report Server, Data Collector, and database display out-of-date copyright information. [PR/1064631: This issue has been resolved.]
  • After importing tunnel path information from the collection files, the traffic engineering (TE) tunnel status is erroneously reported in the On Pref Rt field as “not routed”. [PR/1064871: This issue has been resolved.]
  • WANDL IP/MPSView Release 6.1.2S is missing the Jump Server. [PR/1066101: This issue has been resolved.]
  • Selecting Network > Nodes in the Web Portal sometimes displays the incorrect Admin Status. [PR/1067442, PR/1093980: This issue has been resolved.]
  • WANDL IP/MPLSView cannot accurately recognize the RSVP label-switched path (LSP) bandwidth if Auto Bandwidth is enabled. [PR/1069236: This issue has been resolved.]
  • The Mongo database does not start as expected when a lingering process is running in the background. [PR/1073326: This issue has been resolved.]
  • When running the LDP Traffic Collection Task with the Use ECMP option enabled, LDP demands are generated without the equal-cost multipath (ECMP) flag as expected. [PR/1075697: This issue has been resolved.]
  • Customer requests the ability to directly add configuration files from the Compliance Assessment Tool window. [PR/1080074: This issue has been resolved.]
  • Customer requests that when you open the Compliance Assessment Tool, a pop-up window should open that enables you to select the project to open. [PR/1080075: This issue has been resolved.]
  • Customer requests that when you open the Template Designer, a pop-up window should open that enables you to select the project to open. [PR/1080076: This issue has been resolved.]
  • When you attempt to add a Layer 3 VPN with the same name as a VPN that you previously deleted from the topology, the new VPN is not added to the topology as expected. [PR/1080684: This issue has been resolved.]
  • Unexpected output is displayed in the Choose Value(s) window of the Web Event Browser. [PR/1081217: This issue has been resolved.]
  • When running a configuration statistics collection task in Task Manager, some nodes are not added to the inventory even though the collection task completed successfully. [PR/1081355: This issue has been resolved.]
  • When exporting to the Web, an error message is unexpectedly displayed requesting that the user contact JTAC for assistance. [PR/1081356: This issue has been resolved.]
  • Running the SNMP Collection task on a TX Matrix Plus router unexpectedly fails, and displays the error message “No CPU/MEM values obtained from the device”. [PR/1082527: This issue has been resolved.]
  • Issuing the /u/wandl/bin/eraseNode.sh command fails to delete the associated configuration file as expected. [PR/1092195: This issue has been resolved.]

Modified: 2015-07-13