Technical Documentation

SONET/SDH OC12c/STM4 PICs (M40e Router)

Figure 1: 1-Port SONET/SDH OC12c/STM4 PIC

Image g001194.gif

Figure 2: 4-Port SONET/SDH OC12c/STM4 PIC

Image g001810.gif

Software release

  • Junos OS Release 5.2 and later

Description

  • One or four ports
  • Power requirement: 0.23 A @ 48 V (10.8 W)

Hardware features

  • Multiplexing and demultiplexing
  • Rate policing on input
  • Rate shaping on output
  • Packet buffering, Layer 2 parsing

Software features

  • SONET/SDH framing
  • Link aggregation
  • Alarm and event counting and detection
  • Dual-router automatic protection switching (APS)
  • Multiprotocol Label Switching (MPLS) fast reroute
  • Encapsulations:
    • High-Level Data Link Control (HDLC)
    • Frame Relay
    • Circuit cross-connect (CCC)
    • Translational cross-connect (TCC)
    • Point-to-Point Protocol (PPP)

Cables and connectors

Note: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in the Junos System Basics and Services Command Reference.

LEDs

One tricolor per port:

  • Off—Not enabled
  • Green—Online with no alarms or failures
  • Yellow—Online with alarms for remote failures
  • Red—Active with a local alarm; router has detected a failure

Alarms, errors, and events

  • SONET alarms:
    • Alarm indication signal—line (AIS-L)
    • Alarm indication signal—path (AIS-P)
    • Bit error rate signal degrade (BERR-SD)
    • Bit error rate signal fail (BERR-SF)
    • Bit interleaved parity (BIP) error B1
    • Bit interleaved parity (BIP) error B2
    • Bit interleaved parity (BIP) error B3
    • Loss of frame (LOF)
    • Loss of pointer (LOP-P)
    • Loss of signal (LOS)
    • Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
    • Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
    • Payload mismatch (path label mismatch) (PLM-P)
    • Payload unequipped (unequipped STS at path level) (UNEQ-P)
    • Remote defect indication—line (RDI-L)
    • Remote defect indication—path (RDI-P)
  • SDH alarms:
    • Multiplex section alarm indication signal (MS-AIS)
    • Administrative unit alarm indication signal (AU-AIS)
    • Bit error rate signal degrade (BERR-SD)
    • Bit error rate signal fail (BERR-SF)
    • Bit interleaved parity (BIP) error B1
    • Bit interleaved parity (BIP) error B2
    • Bit interleaved parity (BIP) error B3
    • Loss of frame (LOF)
    • Loss of pointer (HP-LOP)
    • Loss of signal (LOS)
    • Multiplex section remote error indication (MS-REI)
    • Higher path label mismatch (HP-PLM)
    • Higher path unequipped (HP-UNEQ)
    • Multiplex section remote defect indication (MS-RDI)
    • Higher path remote defect indication (HP-RDI)
  • Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
  • Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)

Published: 2010-08-14

Help
|
My Account
|
Log Out