    SRX3600 服务网关上的 NPC 故障排除

    要排除 NPC 故障,请按照以下准则操作:

    • 确保 NPC 正确安放在背板,并且其螺丝已拧紧。
    • 输入 CLI show chassis fpc 命令及槽位号检查已安装 NPC 的状态。 如示例输出所示,值 Online (标记为 状态 的列中)表示 NPC 正常工作:
      user@host> show chassis fpc 5
                    Temp  CPU Utilization (%)   Memory    Utilization (%)
      Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
        5  Online            42      6          0       1024       16         57
       

      要获得更详细的输出,请添加 detail 选项。 未指定槽位号时,此选项是可选的:

      user@host> show chassis fpc 5 detail

      Slot 5 information: State Online Temperature 42 degrees C / 107 degrees F Total CPU DRAM 1024 MB Total RLDRAM 256 MB Total DDR DRAM 4096 MB Start time: 2007-07-10 12:28:42 PDT Uptime: 1 hour, 33 minutes, 43 seconds

      有关这些命令的输出的更详细说明,请参阅 Junos OS 系统基础知识和服务命令参考