Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 
 

show fibre-channel fip fabric

Syntax

Description

Display Fibre Channel over Ethernet (FCoE) Initialization Protocol (FIP) information for a specified Fibre Channel fabric.

Options

brief | detail

(Optional) Display the specified level of output.

fabric-name

Display information for the specified fabric.

Required Privilege Level

view

Output Fields

Table 1 lists the output fields for the show fibre-channel fip fabric command. Output fields are listed in the approximate order in which they appear.

Table 1: show fibre-channel fip fabric Output Fields

Field Name

Field Description

Level of Output

Fabric Name

Name of the fabric and in parentheses the fabric ID.

All

FC-MAP

FCoE mapped address prefix of the FCoE forwarder for the fabric.

detail

FKA-ADV-PERIOD

Period of time in milliseconds between FIP keepalive advertisements configured for the FC fabric.

detail

Member

 

Information about an FCF that is a member of the fabric.

All

  • FCF-MAC

MAC address used in discovery advertisements.

All

  • FKA-ADV-PERIOD

Period of time in milliseconds between FIP keepalive advertisements configured for the FC interface.

detail

  • FKA-ADV-D-BIT

Disable FIP keepalive advertisement monitoring bit. The state is always off.

detail

  • Type

Type of interface:

  • VF_Port Capable—Interface can act as a VF_Port interface.

detail

ENode

 

Information about a connected FCoE node (ENode).

All

  • ENode-MAC

MAC address of the connected ENode.

All

  • State

Login state internal to Junos OS.

All

  • VN-Port-MAC

MAC address of a VN_Port on the ENode.

detail

  • Session State

Session state internal to Junos OS.

detail

  • Configured FKA-ADV

User-configured FIP keepalive advertisement interval in milliseconds.

detail

  • Running FKA-ADV

Runtime interval in seconds of the last FIP keepalive advertisement received. This value changes every time an FKA_ADV is received.

detail

  • Configured VN-Port Timer

Configured state of the VN_Port keepalive timer in seconds. This value is always 90 and is not user-configurable.

detail

  • Running VN-Port Timer

Running state of the VN_Port keepalive timer in seconds.

detail

Sample Output

show fibre-channel fip fabric proxy2

show fibre-channel fip fabric detail

Release Information

Command introduced in Junos OS Release 11.1.