General Routing

  • JDI_REG::QFX5200:: After ISSU upgrade, device is hanged and not able to perform any operations until USB recovery done on device PR1703229

  • EX3400: "Error:tvp_optics_eeprom_read: Failed to read eeprom for link" syslog error message PR1757034

  • Establishing virtual-chassis connection between EX4300-MP platforms, the traffic sent via the VCP port is lost minimally PR1805100

  • [interfaces] EX4100-H-12MP : :: Rampur: "dc-pfe[22751]: BCM Error: API bcm_plp_mode_config_get(phy_name, plp_info, &speed, &intf_type, &r_clk, &if_mode, &aux) at tvp_bcm_mgig_phy_basic_init:433 -> -25 " Error message is seen during image upgrade PR1812228

  • Packet drops when jumbo frames forwarded through ge interfaces configured for 10/100Mbps speed PR1812891

  • Complete packet loss will be observed for the inter-VLAN traffic in EVPN-VXLAN CRB scenario PR1820830

  • Protocol traffic drops were seen in the network for any configuration change in the protocol PR1823601

  • Interface goes down after a dc-pfe (Data Centre Packet Forwarding Engine) process restart in a Virtual Chassis environment on EX4400 platform PR1823688

  • The SFP 10GBASE-T part No. 740-083295 on platforms running Junos/Junos EVO is unable to detect a linkdown PR1823771

  • Random ports of EX4400 will not be created on upgrade or reboot PR1825281

  • On an EX4400 device with 4x25G Uplink module configured in 1GE or 25G speed, peer side of an interface with 10GBASE-T transceiver may remain up even when the IFD(xe-x/2/y) is not created PR1831409

  • EX2300/EX3400 : The status LED of uplink port is not working properly PR1833177

  • Continuous increment of tcpAttemptFails counter on Junos EX2300 and 3400 PR1839618

  • Delay in GBP installation in an EVPN-VXLAN scenario PR1839916

  • PFE process crash is observed when web-management is not configured in a CWA setup PR1840988

  • TDR test can cause a CPU hog and result in BFD flaps PR1841117

  • Junos OS and Junos OS Evolved: Receipt of a specifically malformed DHCP packet causes jdhcpd process to crash (CVE-2025-30648) PR1842682

  • Media Access Control Security (MACsec) does not work properly after a transceiver is removed and re-inserted PR1844354

  • EX4100 looses connectivity with the directly connected management port of QFX5120-48Y series platform PR1844709

  • Lane laser temperature value is incorrectly displayed in the snmp query PR1844751

  • The push pop function on the QFX5120 and EX4650 is not correctly pushing the VLAN PR1844853

  • PEM mismatch alarms vanished after performing system reboot on member PR1845365

  • Interface not added back to AE bundle with multiple changes in single commit PR1845370

  • The error message will be seen on EX4100 platforms when deactivating/activating IRB interfaces PR1846286

  • Memory Leak: Memory leak is detected with rpd task blocks "rpd-trace" PR1846294

  • Reachability issues are seen on interfaces that are aggregated without address-family PR1847159

  • Junos EX platform will display multiple intermittent Fan overspeed alarms PR1848292

  • EX4400: Storm-control is created for the GE interfaces for 4x10G uplink modules. PR1848338

  • IGMP snooping stops working after reboot PR1848764

  • Handling AE Child Members, VT port properties reset when Access Port is destroyed PR1849952

  • EX4400 uplink ports (PIC 2) with the 4x25G uplink module may go down when SFPs (SFP+-10G-BX10-D/U or SFP+-10G-BX40-D/U) are inserted. PR1849992

  • EX3400 Dot1x Radius accounting send incorrect value to the server for Acct-Input-Gigawords/ Acct-Output-Gigawords PR1851299

  • The l2ald process crash is observed when same Type 5 MAC-IP received with same IP and different MAC PR1852019

  • VoIP Phones are unable to receive an IP address with or without dot1x configuration PR1852215

  • Devices fail to obtain an IP address when DHCP Security Option 82 is enabled PR1854253

  • In Junos EX and QFX platforms, when ERPS protocol is enabled on a ISL trunk, the commit command fails PR1855088

  • PoE ports go down when only PSU in slot 1 is connected PR1855409

  • Traffic drop observed due to ECMP next-hop programming issue PR1855990

  • Error logs : "PFE_BRCM_COS_HALP_ERR: BRCM_COS_HALP" are observed and CoS not working on EX2300 switches PR1856201

  • Port mirroring fails due to mismatched analyzer and outgoing interface configuration PR1856361

  • L2ald process crash is observed upon executing hidden command "show ethernet-switching debug-statistics fast-mac-update" in case the command doesn't have any output PR1864295

  • STP/MSTP/RSTP/VSTP convergence issue due to BPDU drop by l2cpd PR1864371

  • Default Route configured with Discard Next Hop on PFE instead of ECMP Next Hop after reboot PR1867562

  • Traffic will be dropped due to IPv4 header checksum mismatch on EX4400 platform PR1870016

  • RPD might crash when upgrading using no-validate. PR1870183

  • Inserting any unsupported optics in 4x25G ULM will cause any port on the ULM to go down PR1877524

Infrastructure

  • Junos OS: A local attacker with shell access can execute arbitrary code (CVE-2025-21590) PR1872010

Layer 2 Ethernet Services

  • Unable to assign an IP address on management interface with DHCP configuration even if DHCP is bound after a power cycle PR1854827

  • DNS resolution will fail for DNS entries written to "resolv.conf" PR1872292

  • AE member not able to discover lost LACP peer connection leading to traffic black-holing PR1874126

Platform and Infrastructure

  • Traffic drops after link flap on active-active ESI setup with MAC pinning enabled PR1846365

  • User root is shown as incorrect after power cycle of the device PR1855393

  • STP/RSTP/MSTP/VSTP enters a disputed and blocked state when the anchor FPC of an AE link, with members distributed across multiple FPCs, goes offline PR1870522

Routing Protocols

  • Memory leak is seen when BGP is activated and deactivated PR1849027

  • BGP queue deadlock on Junos/Junos OS Evolved/cRPD platforms leading to route advertisement failure and traffic loss PR1860786

  • Disabling the PIM interface underneath the [edit protocols pim interfaces <intf-name>] hierarchy may still show PIM as still being UP instead of DOWN. PR1857699

User Interface and Configuration

  • Unexpected issues such as login failures or disabled interfaces observed following abrupt reboot during commit operation PR1861063

  • The show system storage command output should show only true and distinct storages. PR1873253