Resolved Issues
Learn about the issues fixed in this release for NFX Series.
For the most complete and latest information about known Junos OS defects, use the Juniper Networks online Junos Problem Report Search application.
General Routing
-
The dcpfe process on the NFX350 platforms crashes when the device undergoes a shutdown or a reboot.PR1807738
-
On NFX250 and NFX350 platforms, the command
clear interfaces statistics all
is not executed within the expected time (i.e. 1-2 seconds). There is no traffic impact due to this issue.PR1818888
High Availability (HA) and Resiliency
-
When high availability (HA) is enabled and fabric links are configured on NFX devices ( NFX150, NFX250 and NFX350 with nfx-3 software package), the fabric link monitored status is displayed as Down leading to an FL status. PR1794559
VNF
-
On all the NFX platforms with LTS19 image, the VNF (Virtual Network Function) OVS (Open vSwitch) interfaces fail to come up when more than 4Gb of memory is allocated to the VNF. This affects the traffic flow.PR1799045