General Routing

  • On ACX2200 series, ge (gigabit ethernet) interfaces configured for PTP (Precision Time Protocol), after PTP is deactivated and activated or activated for the first time, traffic can experience packet drops. PR1811850

  • ACX710 Junos OS Platforms reports error clksyncd-service subsystem is not responding to management requests after any new configuration commit causing clksyncd CLI to stuck affecting IPC (Interprocess communication). PR1829340

Network Management and Monitoring

  • Issue: Multiple traps are generated for single event, when more target-addresses are configed in case of INFORM async notifications Cause: INFORM type of async notification handling requires SNMP agent running on router to send a Inform-Request to the NMS and when NMS sends back a get-response PDU, this need to be handled. In this issue state, when more than one target-address(NMS IP) is configured for a SNMP v3 INFORM set of configuration, when Get-Response comes out of order in which the Inform-Request is sent, the PDU is not handled correctly causing snmp agent to retry the Inform-request. This was shows as multiple traps at the NMS side. Work-around: For this issue would be to use 'trap' instead of 'inform' in the "set snmp v3 notify NOTIFY_NAME type inform" CLI configuration.PR1773863

Virtual Chassis

  • The ACX5000 reports false parity error messages such as soc_mem_array_sbusdma_read. The ACX5000 SDK can raise false alarms for parity error messages such as soc_mem_array_sbusdma_read. This is a false positive error message. PR1276970