Known Limitations
Learn about known limitations in this release for SRX Series Firewalls.
For the most complete and latest information about known Junos OS defects, use the Juniper Networks online Junos Problem Report Search application.
Flow-Based and Packet-Based Processing
-
The rst_sequence command request SPU flow to keep having sequence number in the record. But, for sessions which has been offloaded, the packet is forwarded directly on NP, due to which SPU did not receive the packet. Also, the sequence number is not synchronize to the SPU session. PR1830053
User Interface and Configuration
-
On SRX300 line of devices, when running BFD, performing CLI commands which have a long output and high impact on control plane CPU load, might cause a BFD flap. In such case, use the Dedicated BFD or Real-time BFD feature to avoid the impact. PR1657304