ON THIS PAGE
Resolved Issues
Learn about the issues fixed in this release for NFX Series.
For the most complete and latest information about known Junos OS defects, use the Juniper Networks online Junos Problem Report Search application.
Interfaces
-
Starting in Junos OS Release 24.2R1 release, when you run the command
show chassis alarm
on NFX 350 devices, the output displaysMajor TSensor 3:Coretemp Access Failed
due to swapping of the symlinks of hwmon0 and hwmon1.PR1769699
Network Address Translation
On the NFX devices when the NAT port number or the IP address of the peer device located behind a Network address translation (NAT) device is changed, the next Dead Peer Detection (DPD) or rekey process fails to update the port number in the existing tunnel NAT Traversal (NAT-T) flow session. The failure to update the port-number happens if the DPD is configured as
PR1776216always-send
. This condition leads to communication failure over the Internet Protocol Security (IPsec) tunnel.
VNF
-
On the NFX platforms, the
pfe
(Packet Forwarding Engine) process crashes when configured with custom mode templates like flex mode or any other custom mode due to memory exhaustion. PR1776815