Interfaces
-
On the NFX250, the LACP subsystem does not start automatically when the dc-pfe process is restarted.
Workaround—Deactivate and then activate the aggregated Ethernet interface.
General Routing
-
On the NFXplatforms when one partition supports a Junos OS Release 23.4R1 image (supported on LTS19 operating sytem) and the other partition supports an image older than Junos OS Release 23.4R1 (supported on WRL8 operating system), the request vmhost reboot disk command is not executed as expected PR1753117..
-
On the NFX350 devices,
srxpfe core
is seen.PR1792616. -
On the NFX350 devices,
libvirtMib_suba.core.tgz
is seen.PR1675919
High Availability (HA) and Resiliency
-
When high availability (HA) is enabled and fabric links are configured on NFX devices ( NFX150, NFX250 and NFX350 with nfx-3 software package), the fabric link monitored status is displayed as
Down
leading to anFL
status.PR1794559
VNF
-
In Junos OS Release 23.4R1, on NFX devices with nfx-3 architecture, cpu utilization by vcpu thread of vjunos0 is high. Same behavior may be observed with the vcpu thread of any VNF.PR1727654