What's Changed
Learn about what changed in this release for QFX Series switches.
EVPN
-
Multicast debug information added in EVPN options to request system information command (QFX Series)—The output from CLI command
request support information evpn-vxlannow includes additional information to help debug EVPN multicast issues.[See request support information.]
-
Configure
conserve-mcast-route-in-pfeoption on OISM server leaf and border leaf devices in scaled EVPN-VXLAN fabrics to avoid multicast route exhaustion (QFX5130-32CD and QFX5700 switches)—You can configure QFX5130-32CD and QFX5700 switches as optimized intersubnet multicast (OISM) server leaf or border leaf devices in an EVPN-VXLAN fabric. In scaled fabrics with many VLANs, EVPN instances, and multicast streams, you might see multicast traffic loss on these devices due to the limited size of the multicast snooping route tables in the PFE. To avoid this problem on QFX5130-32CD and QFX5700 switches with OISM in scaled environments, we require that you configure the <cli>conserve-mcast-routes-in-pfe</cli> option at theedit multicast-snooping-options oismhierarchy on these platforms. This option is available only on QFX5130-32CD and QFX5700 switches. Use this option when you configure these devices as server leaf or border leaf devices with OISM. Do not configure this option when you configure these devices as standalone assisted replication (AR) replicators with OISM.
General Routing
-
Label for the hours unit of time displayed in output— When there are zero minutes in the output for the
show system uptimecommand, the label for the hours unit of time is displayed.[See show system uptime.]
-
Prior to this change the output of a
show task replication | display xml validatereturned an error of the form ERROR: Duplicate data element <task-protocol-replication-name>. With this change the XML output is properly structured with no validation errors. -
The active-user-count is defined as a numeric integer value in ODL request output— The output for the get-system-uptime-information ODL request contains information for the active-user-count. The active-user-count is now defined as a numeric integer value and avoids an invalid value type error.
[See show system uptime.]
-
Two new alarms are added and can be seen with MPC11E when 400G-ZR optics are used. High Power Optics Too Warm: warning of the increase in chassis ambient temperature with no functional action taken on the optics Temperature too high for optics power on: New inserted optics when the chassis ambient temperature is elevated beyond the threshold will not be powered on and would need to be reinserted when the ambient temperature is within the acceptable range
Junos XML API and Scripting
-
Ability to commit
extension-service fileconfiguration when application file is unavailable—When you set theoptionaloption at the[edit system extension extension-service application file varname file-name]hierarchy level, the operating system can commit the configuration even if the file is not available at the /var/db/scripts/jet file path.[See file (JET).]
-
Ability to restart restart daemonized applications—Use the
request extension-service restart-daemonize-app application-namecommand to restart a daemonized application running on a Junos OS Evolved device. Restarting the application can assist you with debugging and troubleshooting. -
The
xmlns:junosattribute includes the complete software version string (ACX Series, PTX Series, and QFX Series)—Thexmlns:junosnamespace string in XML RPC replies includes the complete software version release number, which is identical to the version emitted by theshow versioncommand. In earlier releases, thexmlns:junosstring includes only partial software version information.
Network Management and Monitoring
-
The connectivity fault management process (cfmd) runs only when the ethernet connectivity-fault-management protocol is configured.
-
Changes to the
show system yang package(get-system-yang-packagesRPC) XML output (ACX Series, PTX Series, and QFX Series)—Theshow system yang packagecommand and<get-system-yang-packages>RPC include the following changes to the XML output:-
The root element is
yang-package-informationinstead ofyang-pkgs-info. -
A
yang-packageelement encloses each set of package files. -
The
yang-pkg-idtag is renamed topackage-id. -
If the package does not contain translation scripts, the Translation Script(s) (
trans-scripts) value isnone.
-
-
NETCONF server's
<rpc-error>response changed when<load-configuration>usesoperation="delete"to delete a nonexistent configuration object (ACX Series, PTX Series, and QFX Series)—In an earlier release, we changed the NETCONF server's<rpc-error>response for when an<edit-config>or<load-configuration>operation usesoperation="delete"to delete a configuration element that is absent in the target configuration. We've reverted the changes to the<load-configuration>response. -
operatorlogin class is restricted from viewing NETCONF trace files that areno-world-readable(ACX Series, PTX Series, and QFX Series)—When you configure NETCONF tracing options at the[edit system services netconf traceoptions]hierarchy level and you restrict file access to the file owner by setting or omitting theno-world-readablestatement (the default), users assigned to theoperatorlogin class do not have permissions to view the trace file. -
Support for the
junos:cli-featureYANG extension (ACX Series, PTX Series, and QFX Series)—Thecli-featureYANG extension identifies certain CLI properties associated with some command options and configuration statements. The Junos YANG modules that define the configuration or RPCs include thecli-featureextension statement, where appropriate, in schemas emitted with extensions. This extension is beneficial when a client consumes YANG data models, but for certain workflows, the client needs to generate CLI-based tools.