General Routing

  • Two new alarms are added and can be seen with MPC11E when 400G-ZR optics are used. High Power Optics Too Warm: warning of the increase in chassis ambient temperature with no functional action taken on the optics Temperature too high for optics power on: New inserted optics when the chassis ambient temperature is elevated beyond the threshold will not be powered on and would need to be reinserted when the ambient temperature is within the acceptable range

  • The packet rate and byte rate fields for LSP sensors on AFT (with the legacy path) have been renamed as jnx-packet-rate and jnx-byte-rate and is in parity with the UKERN behavior. Previously, these rate fields were named as packetRate and byteRate.

  • Before this change most list were ordered by the sequence in which the user configured the list items, for example a series of static routes. After this change the list order is determined by the system with items displayed in numerical sequence rather than by the order in which the items were configured. There is no functional impact to this change.

  • Label-switched interface (LSI) delay during reboot (ACX Series) — Rebooting ACX Series routers running Junos OS Evolved with a class-of-service routing-instance configuration might encounter errors due to a delay with the label-switched interface (LSI). LSI state information has been added to the output of the show route instance command to assist in the analysis of such errors.

    [See show route instance.]

Junos XML API and Scripting

  • Ability to commit extension-service file configuration when application file is unavailable—When you set the optional option at the edit system extension extension-service application file file-name hierarchy level, the operating system can commit the configuration even if the file is not available at the /var/db/scripts/jet file path.

    [See file (JET).]

  • Ability to restart restart daemonized applications—Use the request extension-service restart-daemonize-app application-name command to restart a daemonized application running on a Junos device. Restarting the application can assist you with debugging and troubleshooting.

    [See request extension-service restart-daemonize-app.]

Network Management and Monitoring

  • Changes to the NETCONF server's <rpc-error> element when the operation="delete" operation deletes a nonexistent configuration object (ACX Series, EX Series, MX Series, PTX Series, QFX Series, SRX Series, vMX, and vSRX )—We've changed the <rpc-error> response that the NETCONF server returns when the <edit-config> operation uses operation="delete" to delete a configuration element that is absent in the target configuration. The error severity is error instead of warning, and the <rpc-error> element includes the <error-tag>data-missing</error-tag> and <error-type>application</error-type> elements.

  • Changes to the RPC response for <validate> operations in RFC-compliant NETCONF sessions (ACX Series, EX Series, MX Series, PTX Series, QFX Series, SRX Series, vMX, and vSRX )—When you configure the rfc-compliant statement at the [edit system services netconf] hierarchy level, the NETCONF server emits only an <ok/> or <rpc-error> element in response to <validate> operations. In earlier releases, the RPC reply also includes the <commit-results> element.