Class of Service (CoS)

  • On all Junos OS platforms, in a scaled scenario when some of the ge/xe/et interfaces are members of aggregated Ethernet (AE) and the Class of Service (CoS) forwarding-class-set configuration is applied with a wildcard for all the physical interfaces and aaggregated Ethernet, it might trigger a Flexible PIC Concentrators (FPC) crash which leads to traffic loss. PR1688455

EVPN

  • On QFX10002/QFX10008/QFX10016 (only QFX10K) platforms, when Assisted Replication (AR) feature as Replicator role is used in an Ethernet VPN (EVPN) multi-homed scenario, You can see out-of-bound memory access issue that might result in the kernel crash leading to the service impact.PR1649234

General Routing

  • When VLAN is added as an action for changing the VLAN in both ingress and egress filters, the filter is not installed. PR1362609

  • On the QFX5100 line of switches, inserting or removing optics on a port might cause a Packet Forwarding Engine Manager CPU spike and an eventual microcode failure. PR1372041

  • VXLAN VNI (multicast learning) scaling on QFX5110 traffic issue is seen from VXLAN tunnel to Layer 2 interface. PR1462548

  • 5M DAC connected between QFX10002-60C and MX2010 doesn't link up. But with 1M and 3M DAC this interop works as expected. Also it is to be noted QFX10002-60C and ACX or Traffic generator the same 5M DAC works seamlessly. There seems to be certain SI or link level configuration on both QFX10002-60C and MX2010 which needs to be debugged with the help from HW and SI teams and resolved. PR1555955

  • To avoid the additional interface flap , interface hold time needs to be configured . PR1562857

  • On QFX5100, Media type for SFP+-10G-CU1M and SFP-T cables are shown as Fiber. This is only a display issue and no functionality impact is observed.PR1570555

  • On a QFX5120, when you disable a protected link. You may see a delay of 200-400 mSec for the system to react to the disable link event.PR1579931

  • In a fully loaded devices, at times, firewall programming was failing due to scaled prefix configuration with more than 64800 entries. However, this issue is not observed in development setup. PR1581767

  • On QFX5110 VC, FPC may gets disconnected with 24K DHCPv6 relay scaling, after the traffic is stopped. "pfe_listener_disconnect" error messages may be seen.PR1594748

  • Pim VxLAN not working on TD3 chipsets enabling VxLAN flexflow after Junos OS Release 21.3R1. Customers Pim VxLAN or data plane VxLAN can use the Junos OS Release 21.3R1. PR1597276

  • On QFX5100, optical power is seen after detached and attached QSFP on disable interface. PR1606003

  • On QFX5120-48Y, when scaled config and baseline configs are loaded multiple times one after other without much wait time in between then traffic or protocols on pure L3 interfaces may behave in undefined/unexpected manner. PR1612973

  • On Junos QFX10k platforms with scaled number of BFD (Bidirectional Forwarding Detection) sessions configured, addition of a new BFD session might cause flapping in newly added session and other existing BFD sessions.PR1621976

  • QFX5110-32Q : Traffic loss seen after renumbering master in VCPR1632565

  • Backup FPC lose their connection to the master when new members are added to the VCF (Virtual Chassis Fabric).PR1634533

  • The bounded delay config feature for IFL is not supported on Pyrite platform. The core is seen only when this config is enabled on the device. PR1634941

  • On all devices running Junos OS or Junos OS Evolved, where this is a high BGP scale with flapping route and the BGP Monitoring Protocol (BMP) collector/station is very slow, the rpd process might crash due to memory pressure.PR1635143

  • When a 100G interface on a QFX5120 is converted to a VC port, the interface stays down as the port is configured as 40G internally. PR1638156

  • On all QFX5100 Virtual Chassis platforms, after the reboot, Virtual Chassis port (VCP) ports may not establish a VCP connection and Cyclic Redundancy Check (CRC) errors are also observed.PR1646561

  • On QFX Series platform, v6 logical interfaces statistics are being derived from the underlying physical interfaces statistics unlike on PTX Series where they are hardware assisted. Therefore, they are not very reliable and are at best, guesstimate. PR1653671

  • After converting access side port from SP style to EP style, MAC-IP learning fails for a host and ARP doesn't get resolved. PR1658657

  • QFX5100-24Q and EX4600 devices Virtual-chassis is in unstable state for 3-7 minutes causing traffic loss. PR1661349

  • On all QFX Series platforms, EVPN Type-5 traffic drops are observed when the device is configured only with Type-5 Virtual Routing and Forwarding (VRF) and without an Integrated Routing and Bridging (IRB) interface. PR1663804

  • When the remote end server/system reboots, QFX5100 platform ports with SFP-T 1G inserted might go into a hung state and remain in that state even after the reboot is complete. This might affect traffic after the remote end system comes online and resumes traffic transmission.PR1665800

  • Native VLAN with VLAN rewrite on same interface not supported. PR1671372

  • On QFX5200, after NSSU upgrade for a 4 member Virtual Chassis, FPC might toggle resulting in interfaces going offline. PR1673116

  • On QFX5120 Virtual Chassis with Open vSwitch Database (OVSDB) VxLAN topology, Address Resolution Protocol (ARP) resolution fails if the traffic passes through VCP (Virtual Chassis Port) ports. As a result, ARP packets are dropped. PR1679684

Layer 2 Ethernet Services

  • On QFX5100 and QFX5110, vendor-id format might be incorrect for network ports. This does not impact the ZTP functionality or service. The DHCP client configuration is coming from two places, that is, AIU script and vsdk sandbox. The DHCP client configuration coming from AIU script has the serial id in vendor id where as the default configuration from sandbox doesn't have.PR1601504

Layer 2 Features

  • In case of the access-side interfaces used as SP-style interfaces, when a new logical interface is added and if there is already a logical interface on the physical interface, there is 20--50 ms traffic drop on the existing logical interface. PR1367488

  • On QFX5100/EX4600 platforms, if a change related to TPID is made in the Device Control Daemon, traffic might be dropped in PFE due to failure on l2 learning or interfaces flapping. PR1477156

Platform and Infrastructure

  • On all Junos and Junos OS Evolved platforms, while using source-address NTP configuration parameter and issue the command "set ntp date" from the CLI, packets will be sent with the source address of the outgoing interface rather than the manually configured IP address. Typically, the manually configured IP address would be a loopback address. The problem does not apply to automatically generated NTP poll packets.PR1545022