General Routing
-
IPv6 primary-only IP address does not move to the new primary Routing Engine after a switchover. PR1648371
-
After configuring
rpf-check
on lag interface, lag interface goes down. PR1652623 -
GNOI rpc KillProcess not supported. PR1655652
-
Routes in RIB and FIB table might go out of sync on all Junos OS Evolved platforms and causes a traffic impact. PR1658426
-
The license might get out of sync between primary and backup Routing Engine. PR1658869
-
Traffic loss due to long MPLS re-route local convergence time on aggregated Ethernet flap. PR1660701
-
The aftmand process crashes upon updating the configurations on the FTI tunnels. PR1663417
-
hwdre and evo-pfemand applications might crash if idmd, fabtoken and hwdre are restarted immediately after a FEB offline. PR1669130
-
PTX10K Scapa : PSM fault state not recoverable PR1669323
-
Fragment frames errors are seen on the 400G interface. PR1671065
-
The traffic loop is observed when ESI is configured on physical interface. PR1672631
-
Reporting-interval in
show jvision sensor info
is stuck at 65000 when configured reporting rate is changed from 65000 to 68000. PR1673476 -
CoS drops seen for priority traffic on some PTX Series platforms. PR1673738
-
Unexpected storage media comsumption caused by system application log. PR1677295
-
Routing Engine reboot, rpd crash, etc. can be seen if the volume of zookeeper logs is high on Junos OS Evolved platforms. PR1678880
-
gnoi-system generates core file during ping requests. PR1680004
-
Destination mask length reported in Sflow exported packet is lesser compared to the value seen in
show route forwarding-table destination
. PR1680040 -
Commit failure on Junos OS Evolved platforms post device upgrade. PR1680266
-
LED status on backup RCB never turns on after reboot. PR1681609
-
Junos OS Evolved PTX Series devices can reboot in a specific scenario.PR1682898
-
Query returned nothing from the database while validating sync_response. PR1683552
-
PTX Series Junos OS Evolved : Major alarm Application ztp fail on node Re0 appears about one day later post system zeroize. PR1683964
-
[CATS]:[JDI_EVO_REG]:[COS]:queue-counters-queued-bytes-rate for network-class is not within the range with cos mru 9200 configuration. PR1691957
-
CBC-FPGA and RE-FPGA firmware upgrades fail. PR1692186
-
CM major errors alarm not raised for pre_init_pll_programming failure with faulty Packet Forwarding E ngine on PTX10004 or PTX10008 or PTX10016 Junos OS Evolved platforms. PR1693511
-
CM alarm is not triggered for Packet Forwarding Engine goes into fault state PR1693710
-
The line cards remain in PRESENT state post reboot. PR1695952
-
The VLAN mapping is incorrect in sflow scenario on PTX Series Junos OS Evolved platforms. PR1696413
-
PTX10004/ PTX10008/ PTX10016 Junos OS Evolved : LC Status LED MIB jnxLEDDescr.3.7.x.0.0 returns undefined 0 value due to read error. PR1696500
-
License key is not installed after upgrade. PR1696879
-
BGP sessions get flapped. PR1697099
-
PTX10004/8/16 Junos OS Evolved : LED on "Status Panel" is Unlit OFF. PR1697503
-
PTX10008 Junos OS Evolved : FTC FPGA minimum supported firmware version mismatch alarm gets generated upon re-seating FTC. PR1698209
-
PTX10004/PTX10008/PTX10016 Junos OS Evolved : SNMP jnxLEDState mib returns 4 (red) value even when BITS LED is unlit/off. PR1698919
Class of Service (CoS)
-
The host outbound traffic drop is seen on all Junos OS Evolved platforms due to a race condition between class-of-service host-outbound-traffic and forwarding-class configuration update. PR1692542
Infrastructure
Interfaces and Chassis
Network Management and Monitoring
-
Interface physical IP address is assigned to SNMP trap source address after chassis restart although source-address lo0 is configured under trap-options. PR1690850
Routing Policy and Firewall Filters
-
The SCUor DCU firewall filter match does not work as expected. PR1699138