Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 
 

What's Changed in Release 22.2R2

Class of Service (CoS)

  • For PTX Series devices running Junos OS Evolved, software priority medium-low maps to hardware priority medium for normal scheduling mode and low for strict priority scheduling mode.

  • Starting in Junos OS Evolved Releases 22.1R3, 22.2R2, and 22.3R1, QFX5130 switches don't copy the Type of Service (ToS) field when encapsulating a VXLAN packet by default. You can enable copying the ToS field upon VXLAN encapsulation using the vxlan-tos-copy-filter statement at the edit forwarding-options hierarchy. This statement copies both the DSCP and ECN values in the ToS field from the IP header of a packet to the outer IP header of the VXLAN packet.

General Routing

  • Change in the help syslog PFE command output—In Junos OS Evolved, the output for help syslog PFE command is fixed to be consistent with Junos OS output on PTX10008 device. ERRMSG tags in EVO are named as SFLOWD_ whereas in Junos they are named as PFE_SFLOW_.

  • sFlow configuration? sFlow configuration is allowed only on et, xe, and ge interfaces in EVO-based platforms. All other interfaces are blocked for configuring sFlow on EVO platforms. A cli error will be thrown if sFlow is configured on any other interface other than et, xe or ge interface.

  • In order to monitor vmhost storage usage: ? A new minor alarm, VMHost RE 0 Disk 1 inode usage breached threshold is introduced ? The existing minor alarm, VMHost RE 0 Disk 1 Usage is above threshold is changed to VMHost RE 0 Disk 1 Size usage breached threshold.

  • Change in the help syslog PFE command output—In Junos OS Evolved, the output for help syslog PFE command is fixed to be consistent with Junos OS output on PTX10008 device. ERRMSG tags in EVO are named as SFLOWD_ whereas in Junos they are named as PFE_SFLOW_.

Junos OS API and Scripting

MPLS

  • Starting with Junos Evolved Release 21.4R3 a CSPF LSP uses a new instance ID when attempting to re-signal a down LSP.

User Interface and Configuration

  • Support for temperature sensor (PTX10001-36MR)—We support the temperature sensor statement at the edit chassis cb hierarchy level. You can use the temperature sensor statement to increase the fan speed and customize the temperature threshold. We recommend certain values for ZR and ZR-M modules to work which helps the temperature to remain within the thresholds.