Resolved Issues: 21.4R1
General Routing
-
Routing Engine switchover does not work as expected while solid-state drive (SSD) failure occurs.PR1437745
-
The device might run out of service post GRES or unified ISSU. PR1558958
-
MPLS jflow packets are dropped on the MPLS interfaces. PR1559390
-
Upgrading PTX1000 platforms with unified SSDs (2x32G SSD) might result in boot loop in certain scenario. PR1571275
-
Mirrored packets get corrupted when a filter is applied with the port-mirror and discard action.PR1576914
-
File permissions are changed for /var/db/scripts files after reboot on PTX platforms. PR1583839
-
High FPC CPU utilization might be seen on PTX10002-60C platform. PR1585728
-
The RPD_KRT_KERNEL_BAD_ROUTE error message is seen in certain scenarios when the rpd process restarts or GRES happens when NSR is enabled. This error has no functional impact. PR1586466
-
The na-grpc process crash might be seen and existing telemetry connections will be disconnected. PR1587956
-
PTX1000 RCB FIPS 140-2 Level 1 - certification support. PR1590640
-
The l2cpd agent might become unresponsive after starting the telemetry service. PR1592473
-
Layer 2 VPN stops forwarding when interface encapsulation is changed to
vlan-ccc
fromethernet-ccc
and back. PR1595455 -
[MPC10E] messages log will be filled with Temp Sensor Fail alarm set/clear and cmtfpc_cpu_core_temp_get: Fail to get temp CPU7_PMB messages. PR1597798
-
On PTX10001-36MR platforms, inconsistency in the platform name used in multiple places, version, snmp mibs, etc. PR1597999
-
On PTX10008 routers, the EVPN-VXLAN shared tunnel commands must be removed. PR1598142
-
On PTX1000 platforms, sFlow data (for example: inner VLAN and outer VLAN value, forwarding-class, and DSCP value) is not exported while checking from server flow records at the collector for ingress sampling. PR1598263
-
The unilist nexthop might get stuck after interface flap on PTX. PR1598309
-
False fan failure alarm flaps (set and cleared) frequently. PR1599183
-
CRC errors increase continuously after interface flap. PR1600768
-
Traffic might get silently dropped and discarded due to the RS Fatal error on FPC-PTX-P1-A, FPC2-PTX-P1A, FPC-SFF-PTX-P1-A, and FPC-SFF-PTX-T. PR1600935
-
The l2circuit packets with PVST and RPVST destination multicast MAC might get dropped. PR1601360
-
OutputInt=0 in JFLOW data reported to collector. PR1601531
-
The IPv6 traffic might get impacted on the PTX platforms when an IPv6 route resolves over a dynamic tunnel. PR1602007
-
Junos OS, PTX10002-60C System: After upgrading, configured firewall filters might be applied on incorrect interfaces (CVE-2021-31382). PR1602292
-
FPC is not fully offline after FPC BAD_VOLTAGE fault is reported. PR1602556
-
In Junos OS, an l2cpd memory leak can occur when specific LLDP packets are received leading to a DoS (CVE-2022-22172). PR1602588
-
Packet loss might be seen on filter-based GRE deployments. PR1603453
-
Traffic loss might be seen on the device due to the continuous errors happening on Fabric Healing process (FHP) phase-1. PR1603499
-
The discard and redirect function might not take effect if changing action from then redirect x.x.x.x to then discard or vice-versa. PR1603872
-
The FPC
pic-mode
configuration might not be committed successfully. PR1605148 -
Link flaps might be observed momentarily on PTX5000 platforms. PR1606008
-
Memory leaks might be observed on the l2cpd process when you perform certain LLDP operations. PR1608699
-
MACsec session might be dropped due to one way congestion. PR1611091
-
The FPC 0 Major Errors alarm might be seen on PTX10002-60C due to a rare timing issue. PR1613229
-
Line-cards might be unstable due to the continuous growing memory usage of evo-cda-bt app. PR1614952
-
VCCV for LDP signaled pseudowire goes down periodically on PTX10008 and PTX10004 with Junos OS. PR1615419
-
90% traffic got dropped when the number of Switch Interface Board (SIB) plane is reduced from 4 to 3 on PTX10008 and PTX10016. PR1615942
-
Slow memory leak (32 bytes each time) of rpd might be seen. PR1616065
-
Memory leak might be seen when LLDP is configured.PR1617151
-
While migration from Junos OS to Junos OS Evolved, customer have to delete chassis redundancy failover or set chassis redundancy failover disable. PR1617720
-
Performance of Jflow service might be impacted on PTX platforms. PR1617932
-
/interfaces/interface/subinterfaces/subinterface/state/counters not exported during initial sync for on-change. PR1620160
-
EAPol packets over l2circuit might get dropped at the tunnel start. PR1628196
-
RPD core might be observed with warm-standby configurations due to reference counting issues. PR1631871
Interfaces and Chassis
-
Junos telemetry interface optics sensor's alarm data type changed from bool_val to str_val. PR1580113
Layer 2 Ethernet Services
MPLS
-
Soft-Preemption does not work after applying
subscription 0
configuration on the RSVP interfaces. PR1587177 -
The LDP replication session might not get synchronized when the dual-transport is enabled.PR1598174
-
VPLS connection might get down if the dual-transport statement is configured.PR1601854
-
LDP does not support policy import with rib-groups. PR1611081
-
IPv4 Prefixes might be associated into both IPv4 and IPv6 LDP database after Routing Engine switchover. PR1611338
-
The RPD crash might happen due to reference count leak in routing table metrics. PR1615001