Services Applications
-
Changes to inline active flow monitoring (PTX Series)—Starting in Junos OS Release 21.3R1, by default no flows are maintained, thereby increasing the number of packets that can be processed. Every sampled packet is considered to be a flow. When the sampled packet is received, the flow is created and immediately timed out as inactive, and the software exports a record to the collector. Therefore, the number of records sent to the collector is higher than before. The IPFIX and version 9 Options Template Data Record now contains 0 in the
Flow Active Timeout
(36) andFlow Inactive Timeout
(37) fields. Therefore, the Options Template Data Record is not compliant with IPFIX RFC 7011.The
show services accounting flow inline-jflow fpc-slot slot-number
operational mode command now displays 0 for all of theActive Flows
andTimed Out
fields. The values of the variousTotal Flows
fields are now equal to their respectiveFlow Packets
field values. The values of the variousFlows Inactive Timed Out
fields are now equal to their respective Flow Packets field values.To change this default behavior and once again create and maintain flows, configure the
nexthop-learning
statement at the[edit services flow-monitoring version- version template template-name]