Connecting a QFX3008-I Interconnect Device to a Fiber-Based QFX3000-G QFabric System Control Plane Network

Before you begin to connect a QFX3008-I Interconnect Device to the fiber-based QFX3000-G QFabric system control plane network:

A QFX3000-G QFabric system control plane and management network is formed by connecting the QFX Series devices in your network to two Virtual Chassis composed of EX4200 or EX4300 switches. If you are creating a fiber-based control plane network, you use eight EX4200-24F or four EX4300-48P Ethernet switches in each Virtual Chassis. QFX3008-I Interconnect Devices have four small form factor pluggable plus (SFP+) management ports on each Control Board (CB0 and CB1). Use the SFP+ management ports to connect the QFX3008-I Interconnect Devices to each Virtual Chassis (see Figure 1).

Figure 1: QFX3000-G QFabric System Fiber-Based Control Plane—Interconnect Device to Virtual Chassis ConnectionsQFX3000-G QFabric System Fiber-Based Control Plane—Interconnect Device to Virtual Chassis Connections

Specific ports have been reserved on the Virtual Chassis to connect to the Interconnect devices, Node devices, and QFX3100 Director devices in your QFabric system. Such design simplifies installation and facilitates timely deployment of a QFabric system. It also enables the use of a standard Virtual Chassis configuration (see Example: Configuring a Fiber-Based Control Plane for the QFX3000-G QFabric System).

To connect each QFX3600-I Interconnect device to the fiber-based control plane network:

Laser Warning:

Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cables connected to transceivers emit laser light that can damage your eyes.

Note:

Before you connect each cable to a device, if the fiber-optic cable connector is covered by a rubber safety cap, remove the cap. If the transceiver is covered with a rubber safety cap, remove the cap. Save the caps for future use.

  1. Connect the first QFX3008-I Interconnect device.
    1. Connect one end of the first fiber optic cable to the SFP optical transceiver in the first management port labeled (labeled 0) on the first Control Board (labeled CB 0).
    2. Connect the other end of that cable to port ge-0/0/19 on the first Virtual Chassis.
    3. Connect one end of the second fiber optic cable to the SFP optical transceiver in the second management port (labeled 1) on CB0.
    4. Connect the other end of that cable to port ge-0/0/19 on the second Virtual Chassis.
    5. Connect one end of the third fiber optic cable to the SFP optical transceiver in the first management port labeled (labeled 0) on the second Control Board (labeled CB 1).
    6. Connect the other end of that cable to port ge-1/0/19 on the first Virtual Chassis.
    7. Connect one end of the fourth fiber optic cable to the SFP optical transceiver in the second management port (labeled 1) on CB1.
    8. Connect the other end of that cable to port ge-1/0/19 on the second Virtual Chassis.
  2. Connect the second QFX3008-I Interconnect device.
    1. Connect one end of the first fiber optic cable to the SFP optical transceiver in the first management port labeled (labeled 0) on the first Control Board (labeled CB 0).
    2. Connect the other end of that cable to port ge-2/0/19 on the first Virtual Chassis.
    3. Connect one end of the second fiber optic cable to the SFP optical transceiver in the second management port (labeled 1) on CB0.
    4. Connect the other end of that cable to port ge-2/0/19 on the second Virtual Chassis.
    5. Connect one end of the third fiber optic cable to the SFP optical transceiver in the first management port labeled (labeled 0) on the second Control Board (labeled CB 1).
    6. Connect the other end of that cable to port ge-3/0/19 on the first Virtual Chassis.
    7. Connect one end of the fourth fiber optic cable to the SFP optical transceiver in the second management port (labeled 1) on CB1.
    8. Connect the other end of that cable to port ge-3/0/19 on the second Virtual Chassis.
  3. (Optional) Connect the third QFX3008-I Interconnect device.
    1. Connect one end of the first fiber optic cable to the SFP optical transceiver in the first management port labeled (labeled 0) on the first Control Board (labeled CB 0).
    2. Connect the other end of that cable to port ge-0/0/18 on the first Virtual Chassis.
    3. Connect one end of the second fiber optic cable to the SFP optical transceiver in the second management port (labeled 1) on CB0.
    4. Connect the other end of that cable to port ge-0/0/18 on the second Virtual Chassis.
    5. Connect one end of the third fiber optic cable to the SFP optical transceiver in the first management port labeled (labeled 0) on the second Control Board (labeled CB 1).
    6. Connect the other end of that cable to port ge-1/0/18 on the first Virtual Chassis.
    7. Connect one end of the fourth fiber optic cable to the SFP optical transceiver in the second management port (labeled 1) on CB1.
    8. Connect the other end of that cable to port ge-1/0/18 on the second Virtual Chassis.
  4. Connect the fourth QFX3008-I Interconnect device.
    1. Connect one end of the first fiber optic cable to the SFP optical transceiver in the first management port labeled (labeled 0) on the first Control Board (labeled CB 0).
    2. Connect the other end of that cable to port ge-2/0/18 on the first Virtual Chassis.
    3. Connect one end of the second fiber optic cable to the SFP optical transceiver in the second management port (labeled 1) on CB0.
    4. Connect the other end of that cable to port ge-2/0/18 on the second Virtual Chassis.
    5. Connect one end of the third fiber optic cable to the SFP optical transceiver in the first management port labeled (labeled 0) on the second Control Board (labeled CB 1).
    6. Connect the other end of that cable to port ge-3/0/18 on the first Virtual Chassis.
    7. Connect one end of the fourth fiber optic cable to the SFP optical transceiver in the second management port (labeled 1) on CB1.
    8. Connect the other end of that cable to port ge-3/0/18 on the second Virtual Chassis.