request chassis fpc
Syntax
request chassis fpc <node (node-id | local | primary)> <offline | online | restart> <slot slot-number>
Description
Control the operation of the Flexible PIC Concentrator (FPC).
The SRX5K-SPC-2-10-40 (SPC1), SRX5K-SPC-4-15-320 (SPC2), and SRX5K-SPC3 does
not support the request chassis
fpc
command.
Options
node |
Change Flexible PIC Concentrator status of specific node. |
offline | Take the FPC or PFE-instance offline. |
online | Bring the FPC or PFE-instance online. |
restart | Restart the FPC or PFE-instance. |
slot slot-number | Specify the FPC slot number. |
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request chassis fpc (SRX Series)
user@host> request chassis fpc online slot 0 FPC 0 already online
Release Information
Command modified in Junos OS Release 9.2.
Command introduced in Junos OS Release 17.2.