frame-error
Syntax
frame-error count;
Hierarchy Level
[edit protocols oam ethernet link-fault-management action-profile ap-name event link-event-rate], [edit protocols oam ethernet link-fault-management interface interface-name event-thresholds ]
Description
Configure the threshold value for sending frame error events or taking the action specified in the action profile.
Frame errors occur on the underlying physical layer. The threshold is reached when the number of frame errors reaches the configured value.
Options
count—Threshold count for frame errors per 100 milliseconds.
Range: 1 through 1000 errors when executed at [edit protocols oam ethernet link-fault-management action-profile ap-name event link-event-rate] hierarchy level.
0 through 100 errors when executed at [edit protocols oam ethernet link-fault-management interface interface-name event-thresholds ] hierarchy level. If you configure 0, then you have disabled the configuration.
Default: 1 error
Required Privilege Level
routing—To view this statement in the configuration.routing-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.4.