tca
Syntax
tca tca-identifier (enable-tca | no-enable-tca) (threshold number | threshold-24hrs number)
Hierarchy Level
[edit interfaces interface-name optics-options]
[edit interfaces interface-name otn-options]
Description
Enable threshold crossing alerts (TCAs) for the following:
Laser power
Laser temperature
Default
By default, TCAs are not enabled.
Options
tca-identifier —At the optics-options hierarchy level, it can be one of the following:
carrier-frequency-offset-high-tca
—Carrier frequency high threshold setting triggercarrier-frequency-offset-low-tca
—Carrier frequency low threshold setting triggerrx-power-high-tca
—Rx power high threshold setting triggerrx-power-low-tca
—Rx power low threshold setting triggertemperature-high-tca
—Temperature high threshold setting triggertemperature-low-tca
—Temperature low threshold setting triggertx-power-high-tca
—Tx power high threshold setting triggertx-power-low-tca
—Tx power low threshold setting trigger
enable-tca | no-enable-tca—To enable or disable the threshold crossing alert.
threshold | threshold-24hrs:
threshold number—Set the 15-minute interval threshold.
threshold-24hrs number—Set the 24-hour interval threshold.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 17.2R1.