show chassis environment fpc

Syntax

Syntax (TX Matrix and TX Matrix Plus Routers)

Syntax (MX Series Routers)

Syntax (MX2010, MX10003, MX204, MX2008, and MX10008, OCX Series, PTX3000, PTX10008 devices and Junos OS Evolved platforms)

Syntax (MX2020 Universal Routing Platforms)

Syntax (QFX Series)

Description

(M40e, M120, M160, M320, MX Series, T Series routers, EX Series, QFX Series, and PTX Series routers only) Display environmental information about Flexible PIC Concentrators (FPCs).

Options

none

Display environmental information about all FPCs. On a TX Matrix router, display environmental information about all FPCs on the TX Matrix router and its attached T640 routers. On a TX Matrix Plus router, display environmental information about all FPCs on the TX Matrix Plus router and its attached routers.

all-members

(MX Series routers only) (Optional) Display environmental information for the FPCs in all the members of the Virtual Chassis configuration.

interconnect-device name

(QFabric systems only) (Optional) Display chassis environmental information for the Interconnect device.

lcc number

(TX Matrix router and TX Matrix Plus router only) (Optional) Line-card chassis number.

Replace number with the following values depending on the LCC configuration:

  • 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix.

  • 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.

  • 0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

  • 0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

local

(MX Series routers only) (Optional) Display environmental information for the FPCs in the local Virtual Chassis member.

member member-id

(MX Series routers only) (Optional) Display environmental information for the FPCs in the specified member of the Virtual Chassis configuration. Replace member-id with a value of 0 or 1.

satellite [fpc-slot slot-id | device-alias alias-name]

(Junos Fusion only)(Optional) Display environmental information for the FPCs in the specified satellite device in a Junos Fusion, or for all satellite devices in the Junos Fusion if no satellite devices are specified.

slot or fpc-slot

(Optional) Display environmental information about an individual FPC:

  • (TX Matrix and TX Matrix Plus routers only) On a TX Matrix router, if you specify the number of the T640 router by using only the lcc number option (the recommended method), replace slot with a value from 0 through 7. Similarly, on a TX Matrix Plus router, if you specify the number of the router by using only the lcc number option (the recommended method), replace slot with a value from 0 through 7. Otherwise, replace slot with a value from 0 through 31. For example, the following commands have the same result:

  • M120 router—Replace slot with a value from 0 through 5.

  • MX240 router—Replace slot with a value from 0 through 2.

  • MX480 router—Replace slot with a value from 0 through 5.

  • MX960 router—Replace slot with a value from 0 through 11.

  • MX2010 router—Replace slot with a value from 0 through 9.

  • MX2020 router—Replace slot with a value from 0 through 19.

  • MX2008 router—Replace slot with a value from 0 through 9.

  • Other routers—Replace slot with a value from 0 through 7.

  • EX Series switches:

    • EX3200 switches and EX4200 standalone switches—Replace slot with 0.

    • EX4200 switches in a Virtual Chassis configuration—Replace slot with a value from 0 through 9 (switch’s member ID).

    • EX6210 switches–Replace slot with a value from 0 through 3 (line card only), 4 or 5 (line card or Switch Fabric and Rotuing Engine (SRE) module), or 6 through 9 (line card only).

    • EX8208 switches—Replace slot with a value from 0 through 7 (line card).

    • EX8216 switches—Replace slot with a value from 0 through 15 (line card).

  • QFX3500 switches —Replace fpc-slot with 0 through 15.

  • PTX5000 Packet Transport Router—Replace fpc-slot with 0 through 7.

  • PTX3000 Packet Transport Router—Replace fpc-slot with 0 through 15.

Required Privilege Level

view

Output Fields

Table 1 lists the output fields for the show chassis environment fpc command. Output fields are listed in the approximate order in which they appear.

Table 1: show chassis environment fpc Output Fields

Field Name

Field Description

State

Status of the FPC:

  • Unknown—FPC is not detected by the router.

  • Empty—No FPC is present.

  • Present—FPC is detected by the chassis daemon but is either not supported by the current version of the Junos OS, or the FPC is coming up but not yet online.

  • Ready—FPC is in intermediate or transition state.

  • Announce online—Intermediate state during which the FPC is coming up but not yet online, and the chassis manager acknowledges the chassisd FPC online initiative.

  • Online—FPC is online and running.

  • Offline—FPC is powered down.

  • Diagnostics—FPC is set to operate in diagnostics mode.

Temperature

(M40e and M160 routers and QFX Series only) Temperature of the air flowing past the FPC.

PMB Temperature

(PTX Series only) Temperature of the air flowing past the PMB (bottom of the FPC).

The PTX5000 Packet Transport Router with FPC2-PTX-P1A include multiple temperatures for PMB (TEMP0 and TEMP1).

PMB CPU Temperature

(PTX5000 Packet Transport Router with FPC2-PTX-P1A only) Temperature of the air flowing past the PMB CPU.

Temperature Intake

(M320 routers, MX2010 routers, MX2020 routers, MX2008 routers, and PTX Series only) Temperature of the air flowing into the chassis.

Temperature Top

(T Series routers only) Temperature of the air flowing past the top of the FPC.

Temperature Exhaust

(M120 and M320 routers, MX2010 routers, MX2020 routers, MX2008 routers, and PTX Series only) Temperature of the air flowing out of the chassis.

The PTX Series Packet Transport Routers, and the MX2010, MX2020, and MX2008 routers include exhaust temperatures for multiple zones (Exhaust A and Exhaust B).

Temperature Bottom

(T Series routers only) Temperature of the air flowing past the bottom of the FPC.

TL n Temperature

(PTX Series only) Temperature of the air flowing past the specified TL area of the packet forwarding engine (PFE) on the FPC.

TQ n Temperature

(PTX Series only) Temperature of the air flowing past the specified TQ area of the packet forwarding engine (PFE) on the FPC.

Temperature MMBO

(T640 router only) Temperature of the air flowing past the type 3 FPC.

Temperature MMB1

(M320 and T Series routers only) Temperature of the air flowing past the type 1, type 2, and type 3 FPC.

Power

Information about the voltage supplied to the FPC. The left column displays the required power, in volts. The right column displays the measured power, in millivolts.

CMB Revision or BUS revision

Revision level of the chassis management bus device (M Series router) or bus (T Series routers).

Sample Output

show chassis environment fpc (M120 Router)

show chassis environment fpc (M160 Router)

show chassis environment fpc (M320 Router)

show chassis environment fpc (MX2020 Router)

show chassis environment fpc (MX2010 Router)

show chassis environment fpc (MX2008 Router)

show chassis environment fpc (MX240 Router)

show chassis environment fpc (MX480 Router)

show chassis environment fpc (MX960 Router MPC10E-15C-MRATE)

show chassis environment fpc (MX960 Router)

show chassis environment fpc (MX480 Router with 100-Gigabit Ethernet CFP)

show chassis environment fpc (MX240, MX480, MX960 with Application Services Modular Line Card

show chassis environment fpc (MX10003 Router)

show chassis environment fpc (MX204 Router)

show chassis environment fpc (MX10008 Router)

show chassis environment fpc (T320, T640, and T1600 Routers)

show chassis environment fpc (T4000 Router)

show chassis environment fpc lcc (TX Matrix Router)

show chassis environment fpc lcc (TX Matrix Plus Router)

show chassis environment fpc (QFX Series and OCX Series)

show chassis environment fpc interconnect-device (QFabric Systems)

show chassis environment fpc 5(PTX3000 Packet Transport Router)

show chassis environment fpc 0 (PTX5000 Packet Transport Router)

show chassis environment fpc 07 (PTX5000 Packet Transport Router with FPC2-PTX-P1A)

show chassis environment fpc (PTX10008 router)

show chassis environment fpc (PTX10016 router)

show chassis environment FPC 1 (MX Routers with Media Services Blade [MSB])

show chassis environment FPC (Junos OS Evolved)

Release Information

Command introduced before Junos OS Release 7.4.