switch (IPLC)
Syntax
switch interface-name | remote;
Hierarchy Level
[edit chassis fpc fpc-slot optical-options wavelength nm]
Description
Switch the specified wavelength from the IPLC port to the specified local or remote optical interface.
The IPLC is designed to connect the ADD and DROP ports
on the front panel to compatible optical PICs or MICs on the local or remote chassis.
Wavelengths configured on the local IPLC ADD ports are multiplexed and
sent over the Line OUT port of the IPLC base module. The remote IPLC
base module receives the signal on the Line IN port and demultiplexes
the wavelengths to the DROP ports on the front panel of the IPLC
according to the configuration of the remote IPLC. After you have made the physical
connections between the IPLC ports and the local and remote optical interfaces, you need
to configure the IPLC to switch the wavelengths to the optical interfaces.
This statement requires you to make the following connections:
-
Install the optical interfaces and configure the wavelength number on the interface so that it is compatible with the wavelength on the IPLC. See Configuring the 10-Gigabit or 100-Gigabit Ethernet DWDM Interface Wavelength. For a list of optical interfaces that are compatible with the IPLC ports, see PTX Series IPLC Compatibility.
-
Install the IPLC module in the local or remote PTX Series chassis and connect the ADD and DROP ports to the respective optical interfaces.
The specified slot must contain an IPLC base module or IPLC expansion module.
Default
Options
| fpc-slot |
Specify the IPLC slot number. |
| interface-name |
Specify the name of the optical interface to which you want to switch the specified wavelength. This field is free-form text. |
| nm |
Specify the wavelength number you want to switch. |
| Remote | Specify that the wavelength is to be switched to an optical interface on a remote chassis. |
Example: Switching Wavelengths to an Optical Interface on the Local Chassis
To switch wavelength 1550.12 on the local IPLC module in slot 2 to the local et-1/1/0 interface, enter the following:
[edit] user@host# set chassis fpc 2optical-options wavelength 1550.12 switch et-1/1/0
Example: Switching Wavelengths to an Optical Interface on the Remote Chassis
To switch wavelength 1550.12 on the local IPLC module in slot 2 to an optical interface on a remote chassis, enter the following:
[edit] user@host# set chassis fpc 2optical-options wavelength 1550.12 switch remote
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Releases 15.1F6 17.1R1.