fpc (Chassis)
Syntax
fpc fpc-slot {
error
max-power <power>
power (off | on)
pfe pfe_id power (off | on)
no-vlan-tagging
pic pic_slot port port_no no-temperature-monitoring
mic slot power off
ignore-poe-feed
}Syntax (ACX Series Devices)
fpc fpc-slot {
cfp-to-et
error
lossless-flow-control
pfe pfe_id
{
power (off | on)
core core_id
{
channel channel_id
tunnel-services
{
bandwidth bandwidth_speed
}
}
}
pic
sampling-instance
power (off | on)
max-power <power>
pfe pfe_id power (off | on)
}Syntax (PTX10003 Devices)
fpc fpc-slot {
error
no-loss {
buffer {
percentage percent;
}
}
power (off | on)
pfe-instance pfe-instance_id | pfe pfe_id power (off| on)
no-vlan-tagging
}Syntax (PTX10004, PTX10008, and PTX10016 Devices)
fpc fpc-slot {
error no-loss {
buffer {
percentage percent;
}
}
pic <slot>
power (off | on)
max-power power
pfe-instance pfe-instance_id power (off| on)
{
port <port_no> no-temperature-monitoring
}
no-vlan-tagging
} Hierarchy Level
[edit chassis]
Description
Configure the FPC slot number. (ACX and PTX Series devices) Configure no VLAN tagging for a specific FPC. Additionally, configure power off configuration (PTX10003 devices only).
Options
Available command options vary based on the device model.
| auto-speed detection |
Disables automatic speed detection. |
| cfp-to-et |
Enable ET interface and remove CFP client. |
| lossless-flow-control |
Lossless buffer config for Ethernet Mac pause. |
| pfe pfe_id core core_id channel channel_id tunnel-services bandwidth bandwidth_speed |
Select a bandwidth speed for your tunnel interface. Speed options start at 1 gigabit. |
| fpc fpc_id |
For PTX devices, fpc_id value is 0 to 15. |
| pfe-instance pfe-instance_id | pfe pfe_id power (off | on) |
Individual PFE Power off configuration. The reset-pfe error action is available for PFE power off and restart. • Slot range for FPC is 0 to 1 for PTX10003-8T. Slot range for FPC is 0 to 3 for PTX10003-16T. • PFE number range is 0 to 7 for all the FPCs. • If no power configuration is present, then PFE is considered powered ON. |
| mic slot power off |
(Only for MX304) Do not provide power to MIC. To power on the MIC, you need to delete this power off configuration. Please note the following information before you commit the changes:
|
| max-powerpower |
Configure maximum power for the FPC slot. Individual PFE maximum power configuration option is available for PTX10003 devices only. |
| no-loss buffer percentage percent |
(PTX10000 Series) Define the percentage of the buffer space reserved for lossless queues. Range: 1-100 percent Default: 10 percent |
| no-vlan-tagging |
Enable no-vlan-tagging on a specific FPC. |
| pic |
Configure properties for an individual PIC. |
| no-temperature-monitoring |
Disable temperature monitoring to explicitly disable optics temperature sensors for EM policy support, on specific WAN ports. |
| ignore-poe-feed |
(EX4100-H-12MP device with 12V-only PSU) Use the system with a 12V-only PSU and clear the alarm when 54V feed is not connected. The configuration is applicable for the entire fpc, including both PSU slots. You cannot configure this to ignore alarms on just one PSU slot. |
Sample Output
Power off MIC (MX304 with LMIC)
user@host# set chassis fpc 0 mic 0 power off
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Platform-Specific fpc (Chassis) Behavior
Use Feature Explorer to confirm platform, and release support for specific features.
Use the following table to review platform-specific behaviors for your platform:
Platform |
Difference |
|---|---|
MX304 devices |
|
Release Information
Statement introduced in Junos OS Evolved Release 24.1R1 for ACX Series Routers.
power-off option introduced for PTX10003 devices in Junos OS Evolved
Release 22.4R1.
tunnel-services and bandwidth options introduced
for ACX Series devices in Junos OS Evolved Release 24.2R1.
mic slot power off
option introduced in Junos OS 24.4R1 for MX304 devices.