wss-express-in (IPLC)
Syntax
wss-express-in ;
Hierarchy Level
[edit chassis fpc fpc-slot optical-options wavelength nm]
Description
Bypass the specified wavelength on this IPLC module. When you bypass a wavelength, it does not terminate at the local node, it is passed on to the next IPLC node. Use this statement to control and manage express traffic at intermediate, two-degree IPLC nodes.
Bypassing wavelengths is supported only on IPLC two-degree nodes running express traffic. For more information, see Configuring a Two-Degree Node for Express Traffic.
Default
Options
| wss-express-in | Bypass the specified wavelength. |
You can bypass only wavelengths that are expressed-in at intermediate, two-degree IPLC nodes.
Example
Bypassing a wavelength is a two-step process:
Configure the two-degree IPLC node for express traffic. See Configuring a Two-Degree Node for Express Traffic.
Bypass the wavelength.
For example, to bypass wavelength 1550.12 on the IPLC module in slot 2 of the two-degree IPLC node:
[edit] user@host# set chassis fpc 2 optical-options wavelength 1550.12 wss-express-in
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Releases 15.1F6 and 17.1R1.