show virtual-chassis
Syntax
show virtual-chassis <status>
Description
Display information about all members of the Virtual Chassis or VCF.
Options
| none | Display information about all Virtual Chassis or VCF member devices. |
| status | Same output
as for |
Required Privilege Level
view
Output Fields
Table 1 lists the output fields for the show virtual-chassis command. Output fields are listed in the approximate order in which
they appear.
Field Name |
Field Description |
|---|---|
Fabric ID |
(VCF only) Assigned ID used to identify the VCF. |
Fabric Mode |
(VCF only) Mode of the VCF: Enabled, Disabled, or Mixed. |
Preprovisioned Virtual Chassis or Preprovisioned Virtual Chassis Fabric |
Virtual Chassis or VCF is configured using preprovisioning. |
Virtual Chassis ID |
Assigned ID that applies to the entire Virtual Chassis or VCF. |
Virtual Chassis Mode |
Mode of the Virtual Chassis or VCF. This field indicates support for the Virtual Chassis feature and, if a Virtual Chassis is configured, if it is a mixed or homogenous Virtual Chassis. Values can be:
|
Member ID |
Assigned member ID and FPC:
|
Status |
For a nonprovisioned configuration:
For a preprovisioned configuration:
|
Serial No |
Serial number of the member device. |
Alias-Name |
The user-configured alias of the member device. The Alias-Name field appears only
if an alias has been configured for at least one device in the Virtual
Chassis or VCF. Aliases are configured using the |
Model |
Model number of the member device. |
Mastership Priority or Mstr prio |
Primary-role priority value of the member device. |
Role |
Role of the member device: primary, backup, or linecard. An asterisk ( * ) following the Role denotes the member device
on which the |
Mixed Mode |
Mixed mode configuration status:
|
Route Mode |
The route mode of the member device:
|
Location |
Location of the member device. If this field is empty, the location field was not set for the device. |
Neighbor List ID and Interface |
Member ID of the neighbor member to which this member’s Virtual Chassis port (VCP) is connected, and the VCP interface name. |
Sample Output
- show virtual-chassis (EX2300 multigigabit model—EX2300-24MP and EX2300-48MP—Virtual Chassis)
- show virtual-chassis (EX2300 and EX2300 multigigabit model (EX2300-24MP, EX2300-48MP) Virtual Chassis)
- show virtual-chassis (EX4200 Virtual Chassis)
- show virtual-chassis (Mixed EX4300 multigigabit model—EX4300-48MP—Virtual Chassis)
- show virtual-chassis (EX8200 Virtual Chassis)
- show virtual-chassis (QFX5110 Virtual Chassis)
- show virtual-chassis (QFX5200 Virtual Chassis)
- show virtual-chassis (QFX5100 Virtual Chassis Fabric)
show virtual-chassis (EX2300 multigigabit model—EX2300-24MP and EX2300-48MP—Virtual Chassis)
user@switch> show virtual-chassis
Virtual Chassis ID: cdef.789a.bc12
Virtual Chassis Mode: Enabled
Mstr Mixed Route Neighbor List
Member ID Status Serial No Model prio Role Mode Mode ID Interface
0 (FPC 0) Prsnt ... ex2300-24mp 128 Backup N VC 3 vcp-255/1/0
1 vcp-255/1/2
1 (FPC 1) Prsnt ... ex2300-48mp 128 Master* N VC 2 vcp-255/1/4
0 vcp-255/1/1
2 (FPC 2) Prsnt ... ex2300-24mp 128 Linecard N VC 3 vcp-255/1/0
1 vcp-255/1/1
3 (FPC 3) Prsnt ... ex2300-48mp 128 Linecard N VC 0 vcp-255/1/4
2 vcp-255/1/5
show virtual-chassis (EX2300 and EX2300 multigigabit model (EX2300-24MP, EX2300-48MP) Virtual Chassis)
user@switch> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: 9876.5432.abcd
Virtual Chassis Mode: Enabled
Mstr Mixed Route Neighbor List
Member ID Status Serial No Model prio Role Mode Mode ID Interface
0 (FPC 0) Prsnt ... ex2300-24mp 129 Backup N VC 1 vcp-255/1/3
3 vcp-255/1/0
1 (FPC 1) Prsnt ... ex2300-24p 129 Master* N VC 2 vcp-255/1/0
0 vcp-255/1/1
2 (FPC 2) Prsnt ... ex2300-24p 0 Linecard N VC 3 vcp-255/1/2
1 vcp-255/1/3
3 (FPC 3) Prsnt ... ex2300-48mp 0 Linecard N VC 2 vcp-255/1/5
0 vcp-255/1/0
show virtual-chassis (EX4200 Virtual Chassis)
user@switch> show virtual-chassis
Virtual Chassis ID: 00ab.cdef.1234
Virtual Chassis Mode: Enabled
Mastership Mixed Neighbor List
Member ID Status Serial No Model priority Role Mode ID Interface
0 (FPC 0) Prsnt ... ex4200-24t 249 Master* N 8 vcp-0
1 vcp-1
1 (FPC 1) Prsnt ... ex4200-24t 248 Backup N 0 vcp-0
2 vcp-1
2 (FPC 2) Prsnt ... ex4200-48p 247 Linecard N 1 vcp-0
3 vcp-1
3 (FPC 3) Prsnt ... ex4200-24t 246 Linecard N 2 vcp-0
4 vcp-1
4 (FPC 4) Prsnt ... ex4200-48p 245 Linecard N 3 vcp-0
5 vcp-1
5 (FPC 5) Prsnt ... ex4200-48t 244 Linecard N 4 vcp-0
6 vcp-1
6 (FPC 6) Prsnt ... ex4200-48t 243 Linecard N 5 vcp-0
7 vcp-1
7 (FPC 7) Prsnt ... ex4200-24f 242 Linecard N 6 vcp-0
8 vcp-1
8 (FPC 8) Prsnt ... ex4200-24f 241 Linecard N 7 vcp-0
0 vcp-1
Member ID for next new member: 9 (FPC 9)show virtual-chassis (Mixed EX4300 multigigabit model—EX4300-48MP—Virtual Chassis)
user@switch> show virtual-chassis
Preprovisioned Virtual Chassis
Virtual Chassis ID: abcd.ef00.1234
Virtual Chassis Mode: Mixed
Mstr Mixed Route Neighbor List
Member ID Status Serial No Model prio Role Mode Mode ID Interface
0 (FPC 0) Prsnt ... ex4300-48mp 129 Master* Y VC 1 vcp-255/1/0
3 vcp-255/1/3
1 (FPC 1) Prsnt ... ex4300-48mp 129 Backup Y VC 0 vcp-255/1/1
2 vcp-255/1/3
2 (FPC 2) Prsnt ... ex4300-48mp 0 Linecard Y VC 3 vcp-255/1/1
1 vcp-255/1/3
3 (FPC 3) Prsnt ... ex4300-48t 0 Linecard Y VC 0 vcp-255/1/0
2 vcp-255/1/2
show virtual-chassis (EX8200 Virtual Chassis)
user@external-routing-engine> show virtual-chassis
Virtual Chassis ID: cdcd.1212.efef
Virtual Chassis Mode: Enabled
Mastership Neighbor List
Member ID Status Serial No Model priority Role ID Interface
0 (FPC 0-15) Prsnt ... ex8216 0 Linecard 8 vcp-0/0
8 vcp-0/1
1 vcp-4/0/4
1 (FPC 16-31) Prsnt ... ex8208 0 Linecard 8 vcp-0/0
0 vcp-3/0/4
8 (FPC 128-143) Prsnt ... ex-xre 128 Master 9 vcp-1/0
1 vcp-1/2
9 vcp-1/3
0 vcp-2/0
9 vcp-2/1
0 vcp-1/1
9 (FPC 144-159) Prsnt ... ex-xre 128 Backup* 8 vcp-1/0
8 vcp-1/2
8 vcp-1/3
8 vcp-1/3
show virtual-chassis (QFX5110 Virtual Chassis)
user@switch> show virtual-chassis
Preprovisioned Virtual Chassis
Virtual Chassis ID: abab.1212.cdcd
Virtual Chassis Mode: Enabled
Mstr Mixed Route Neighbor List
MemberID Status Serial No Model prio Role Mode Mode ID Interface
0 (FPC 0) Prsnt ... qfx5110-32q 129 Backup Y VC 9 vcp-255/0/12
1 vcp-255/0/16
1 (FPC 1) Prsn ... qfx5110-32q 129 Master* Y VC 2 vcp-255/0/16
0 vcp-255/0/17
2 (FPC 2) Prsnt ... qfx5110-32q 0 Linecard Y VC 3 vcp-255/0/11
1 vcp-255/0/14
3 (FPC 3) Prsnt ... qfx5110-32q 0 Linecard Y VC 4 vcp-255/0/14
2 vcp-255/0/31
4 (FPC 4) Prsnt ... qfx5110-32q 0 Linecard Y VC 5 vcp-255/0/10
3 vcp-255/0/5
5 (FPC 5) Prsnt ... qfx5100e-24q-2p 0 Linecard Y VC 6 vcp-255/0/12
4 vcp-255/0/20
6 (FPC 6) Prsnt ... qfx5110-48s-4c 0 Linecard Y VC 7 vcp-255/0/10
5 vcp-255/0/49
7 (FPC 7 Prsnt ... qfx5100e-48s-6q 0 Linecard Y VC 6 vcp-255/0/18
8 vcp-255/0/31
8 (FPC 8) Prsnt ... qfx5110-48s-4c 0 Linecard Y VC 7 vcp-255/0/21
9 vcp-255/0/49
9 (FPC 9) Prsnt ... qfx5110-32q 0 Linecard Y VC 8 vcp-255/0/13
0 vcp-255/0/17
show virtual-chassis (QFX5200 Virtual Chassis)
user@switch> show virtual-chassis
Virtual Chassis ID: abab.1212.cdcd
Virtual Chassis Mode: Enabled
Serial Mstr Mixed Route Neighbor List
Member ID Status No Model prio Role Mode Mode ID Interface
0 (FPC 0) Prsnt ... qfx5200-32c-r 128 Master* N VC 1 vcp-255/0/19
2 vcp-255/0/26
1 (FPC 1) Prsnt ... qfx5200-32c-r 128 Linecard N VC 0 vcp-255/0/20
2 vcp-255/0/16
2 (FPC 2) Prsnt ... qfx5200-32c-32q 128 Backup N VC 0 vcp-255/0/15
1 vcp-255/0/18
show virtual-chassis (QFX5100 Virtual Chassis Fabric)
user@switch> show virtual-chassis
Preprovisioned Virtual Chassis Fabric
Fabric ID: 0123.abcd.4567
Fabric Mode: Enabled
Serial Mstr Mixed Route Neighbor List
Member ID Status No Model prio Role Mode Mode ID Interface
0 (FPC 0) Prsnt ... qfx5100-48s 129 Master* N F 3 vcp-255/1/0
2 vcp-255/1/1
4 vcp-255/1/2
4 vcp-255/1/3
1 (FPC 1) Prsnt ... qfx5100-48s 129 Backup N F 3 vcp-255/1/0
2 vcp-255/1/1
4 vcp-255/1/2
4 vcp-255/1/3
2 (FPC 2) Prsnt ... qfx5100-48s 0 Linecard N F 1 vcp-255/1/0
0 vcp-255/1/1
3 (FPC 3) Prsnt ... qfx5100-48s 0 Linecard N F 1 vcp-255/1/0
0 vcp-255/1/1
4 (FPC 4) Prsnt ... qfx5100-48s 0 Linecard N F 1 vcp-255/1/0
0 vcp-255/1/1
Release Information
Command introduced in Junos OS Release 9.2.
Fabric ID, Fabric
Mode, and Route Mode output fields introduced in Junos OS Release 13.2X51-D20.
Alias-Name output field introduced
in Junos OS Release 14.1X53-D10.