show interfaces statistics fabric
Syntax
show interfaces statistics fabric <brief | detail | terse> <descriptions> <interface-name> <media> <routing-instance (all | instance-name)> <snmp-index snmp-index>
Description
Display status information about the specified fabric interface.
Options
| brief | detail | terse | (Optional) Display the specified level of output. |
| descriptions | (Optional) Display interface description strings. |
| interface-name | (QFabric systems only) The interface name is either the serial number or the alias of the QFabric switch component, such as a Node device, Interconnect device, or QFabric infrastructure. The name must contain a maximum of 128 characters and not contain any colons. |
| media | (Optional) Display media-specific information about network interfaces. |
| routing-instance (all | instance-name) | (Optional) Display all routing instances or the name of an individual routing instance. |
| snmp-index snmp-index | (Optional) Display information for the specified SNMP index of the interface. |
Required Privilege Level
view
Output Fields
Table 1 lists the output fields
for the show interfaces statistics fabric command. Output
fields are listed in the approximate order in which they appear.
Field Name |
Field Description |
Level of Output |
|---|---|---|
| Physical Interface | ||
Physical interface |
Name of the physical interface. |
All levels |
Enabled |
State of the interface. |
All levels |
Interface index |
Index number of the physical interface, which reflects its initialization sequence. |
detail none |
SNMP ifIndex |
SNMP index number for the physical interface. |
detail none |
Link-level type |
Encapsulation being used on the physical interface. |
All levels |
MTU |
Maximum transmission unit size on the physical interface. |
All levels |
Clocking |
Reference clock source. |
detail |
Speed |
Speed at which the interface is running. |
All levels |
Duplex |
Duplex mode of the interface, either Full-Duplex or Half-Duplex. |
All levels |
MAC-REWRITE Error |
Specifies if the encapsulation of the packet has been changed. |
none |
BPDU Error |
Specifies if a BPDU has been received on a blocked interface. |
none |
Loopback |
Loopback status: Enabled or Disabled. If loopback is enabled, type of loopback: Local or Remote. |
All levels |
Source filtering |
Source filtering status: Enabled or Disabled. |
All levels |
Flow control |
Flow control status: Enabled or Disabled. This field is only displayed if asymmetric flow control is not configured. |
All levels |
Device flags |
Information about the physical device. |
All levels |
Interface flags |
Information about the interface. |
All levels |
CoS queues |
Number of CoS queues configured. |
detail none |
Hold-Times |
Current interface hold-time up and hold-time down, in milliseconds. |
detail |
Current address |
Configured MAC address. |
detail none |
Hardware address |
Hardware MAC address. |
detail none |
Last flapped |
Date, time, and how long ago the interface went from down to up. The format is Last flapped: year-month-day hour:minute:second:timezone (hour:minute:second ago). For example, Last flapped: 2008–01–16 10:52:40 UTC (3d 22:58 ago). |
detail none |
Statistics last cleared |
Date, time, and how long ago the statistics for the interface were cleared. The format is Statistics last cleared: year-month-day hour:minute:second:timezone (hour:minute:second ago). For example, 2010-05-17 07:51:28 PDT (00:04:33 ago). |
detail |
Traffic statistics |
Number and rate of bytes and packets received and transmitted on the physical interface.
Note:
The bandwidth bps counter is not enabled. |
detail |
IPv6 transit statistics |
If IPv6 statistics tracking is enabled, number of IPv6 bytes and packets received and transmitted on the logical interface:
Note:
The bandwidth bps counter is not enabled. |
detail |
Input errors |
Input errors on the interface. The following paragraphs explain the counters whose meaning might not be obvious:
|
detail none |
Output errors |
Output errors on the interface. The following paragraphs explain the counters whose meaning might not be obvious:
|
detail none |
Egress queues |
Total number of egress queues supported on the specified interface. |
detail |
Queue counters |
CoS queue number and its associated user-configured forwarding class name.
|
detail |
Input rate |
Input rate in bits per second (bps) and packets per second (pps). |
None specified |
Output rate |
Output rate in bps and pps. |
None specified |
| Logical Interface | ||
Logical interface |
Name of the logical interface. |
All levels |
Index |
Index number of the logical interface, which reflects its initialization sequence. |
detail none |
SNMP ifIndex |
SNMP interface index number for the logical interface. |
detail none |
Flags |
Information about the logical interface. If unicast Reverse Path Forwarding (uRPF) is explicitly configured on the specified interface, the uRPF flag appears. If uRPF was configured on a different interface (and therefore is enabled on all switch interfaces) but was not explicitly configured on the specified interface, the uRPF flag does not appear even though uRPF is enabled. |
All levels |
Input packets |
Number of packets received on the interface. |
detail none |
Output packets |
Number of packets transmitted on the interface. |
detail none |
Input packets |
Number of packets received on the interface. |
detail none |
Output packets |
Number of packets transmitted on the interface. |
detail none |
Encapsulation |
Encapsulation method used on the logical interface.
|
All levels |
Traffic statistics |
Number and rate of bytes and packets received and transmitted on the physical interface.
Note:
The bandwidth bps counter is not enabled. |
detail |
Local statistics |
Note:
The bandwidth bps counter is not enabled. |
detail |
Transit statistics |
Note:
The bandwidth bps counter is not enabled. |
detail |
Addresses, Flags |
Information about the address flags. |
detail none |
protocol-family |
Protocol family configured on the logical interface. If the protocol is inet, the IP address of the interface is also displayed. |
brief |
MTU |
Maximum transmission unit size on the physical interface. |
All levels |
Destination |
IP address of the remote side of the connection. |
detail none |
Local |
IP address of the logical interface. |
detail none |
Broadcast |
Broadcast address of the logical interlace. |
detail none |
Generation |
Unique number for use by Juniper Networks technical support only. |
detail |
Route table |
Route table in which the logical interface address is located. For example, 0 refers to the routing table inet.0. |
detail none |
Sample Output
- show interfaces statistics fabric
- show interfaces statistics fabric brief
- show interfaces statistics fabric detail
- show interfaces statistics fabric terse
- show interfaces statistics fabric device-name
show interfaces statistics fabric
user@switch> show interfaces statistic fabric
Physical interface: IC-WS001:fte-0/0/0, Enabled, Physical link is Down
Interface index: 49174, SNMP ifIndex: 1208484473
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
CoS queues : 12 supported, 12 maximum usable queues
Current address: 00:00:00:00:00:00, Hardware address: 00:00:00:00:00:00
Last flapped : 2012-11-27 20:30:30 UTC (01:55:19 ago)
Statistics last cleared: Never
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
Input errors: 0, Output errors: 0
Logical interface IC-WS001:fte-0/0/0.32768 (Index 83) (SNMP ifIndex 1208484474)
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Input packets : 0
Output packets: 0
Protocol eth-switch, MTU: 0
Physical interface: IC-WS001:fte-0/0/4, Enabled, Physical link is Down
Interface index: 49175, SNMP ifIndex: 1208484363
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
CoS queues : 12 supported, 12 maximum usable queues
Current address: 00:00:00:00:00:04, Hardware address: 00:00:00:00:00:04
Last flapped : 2012-11-27 20:30:30 UTC (01:55:20 ago)
Statistics last cleared: Never
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
Input errors: 0, Output errors: 0
Logical interface IC-WS001:fte-0/0/4.32768 (Index 84) (SNMP ifIndex 1208484364)
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Input packets : 0
Output packets: 0
Protocol eth-switch, MTU: 0
Physical interface: IC-WS001:fte-0/0/6, Enabled, Physical link is Down
Interface index: 49176, SNMP ifIndex: 1208484367
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
CoS queues : 12 supported, 12 maximum usable queues
Current address: 00:00:00:00:00:06, Hardware address: 00:00:00:00:00:06
Last flapped : 2012-11-27 20:30:30 UTC (01:55:20 ago)
Statistics last cleared: Never
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
Input errors: 0, Output errors: 0
Logical interface IC-WS001:fte-0/0/6.32768 (Index 85) (SNMP ifIndex 1208484368)
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Input packets : 0
Output packets: 0
Protocol eth-switch, MTU: 0
Physical interface: IC-WS001:fte-0/0/13, Enabled, Physical link is Down
Interface index: 49177, SNMP ifIndex: 1208484479
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
CoS queues : 12 supported, 12 maximum usable queues
Current address: 00:00:00:00:00:0d, Hardware address: 00:00:00:00:00:0d
Last flapped : 2012-11-27 20:30:30 UTC (01:55:20 ago)
Statistics last cleared: Never
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
Input errors: 0, Output errors: 0
Logical interface IC-WS001:fte-0/0/13.32768 (Index 86) (SNMP ifIndex 1208484480)
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Input packets : 0
Output packets: 0
Protocol eth-switch, MTU: 0
Physical interface: IC-WS001:fte-0/0/15, Enabled, Physical link is Down
Interface index: 49178, SNMP ifIndex: 1208484475
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
CoS queues : 12 supported, 12 maximum usable queues
Current address: 00:00:00:00:00:0f, Hardware address: 00:00:00:00:00:0f
Last flapped : 2012-11-27 20:30:30 UTC (01:55:20 ago)
Statistics last cleared: Never
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
Input errors: 0, Output errors: 0
Logical interface IC-WS001:fte-0/0/15.32768 (Index 87) (SNMP ifIndex 1208484476)
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Input packets : 0
Output packets: 0
Protocol eth-switch, MTU: 0
Physical interface: IC-WS001:fte-1/0/2, Enabled, Physical link is Down
Interface index: 49211, SNMP ifIndex: 1208484377
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
CoS queues : 12 supported, 12 maximum usable queues
Current address: 00:00:00:00:00:02, Hardware address: 00:00:00:00:00:02
Last flapped : 2012-11-27 20:30:47 UTC (01:55:03 ago)
Statistics last cleared: Never
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
Input errors: 0, Output errors: 0
Logical interface IC-WS001:fte-1/0/2.32768 (Index 120) (SNMP ifIndex 1208484378)
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Input packets : 0
Output packets: 0
Protocol eth-switch, MTU: 0
Physical interface: IC-WS001:fte-1/0/7, Enabled, Physical link is Down
Interface index: 49212, SNMP ifIndex: 1208484365
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
CoS queues : 12 supported, 12 maximum usable queues
Current address: 00:00:00:00:00:07, Hardware address: 00:00:00:00:00:07
Last flapped : 2012-11-27 20:30:47 UTC (01:55:04 ago)
Statistics last cleared: Never
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
Input errors: 0, Output errors: 0
Logical interface IC-WS001:fte-1/0/7.32768 (Index 121) (SNMP ifIndex 1208484366)
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Input packets : 0
Output packets: 0
Protocol eth-switch, MTU: 0
Physical interface: IC-WS001:fte-1/0/10, Enabled, Physical link is Down
Interface index: 49213, SNMP ifIndex: 1208484625
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
CoS queues : 12 supported, 12 maximum usable queues
Current address: 00:00:00:00:00:0a, Hardware address: 00:00:00:00:00:0a
Last flapped : 2012-11-27 20:30:47 UTC (01:55:04 ago)
Statistics last cleared: Never
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
Input errors: 0, Output errors: 0
Logical interface IC-WS001:fte-1/0/10.32768 (Index 122) (SNMP ifIndex 1208484626)
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Input packets : 0
Output packets: 0
Protocol eth-switch, MTU: 0
Physical interface: IC-WS001:bme0, Enabled, Physical link is Up
Interface index: 64, SNMP ifIndex: 1208483877
Type: Ethernet, Link-level type: Ethernet, MTU: 1500
Device flags : Present Running
Current address: 02:00:00:00:40:06, Hardware address: 02:00:00:00:40:01
Last flapped : Never
Statistics last cleared: Never
Input packets : 0
Output packets: 26730
Input errors: 0, Output errors: 0
Logical interface IC-WS001:bme0.0 (Index 4) (SNMP ifIndex 1208484065)
Flags: LinkAddress 0-0 Encapsulation: ENET2
Input packets : 2715
Output packets: 18
Protocol inet, MTU: 1482
Local: 128.0.32.0
Logical interface IC-WS001:bme0.1 (Index 5) (SNMP ifIndex 1208484091)
Flags: LinkAddress 0-0 Encapsulation: ENET2
Input packets : 0
Output packets: 999
Protocol inet, MTU: 1482
Addresses
Destination: 128/2, Local: 128.0.0.6, Broadcast: 191.255.255.255
Destination: 128/2, Local: 128.0.130.2, Broadcast: 191.255.255.255
Logical interface IC-WS001:bme0.2 (Index 6) (SNMP ifIndex 1208484092)
Flags: Encapsulation: ENET2
Input packets : 180408
Output packets: 23051
Protocol inet, MTU: 1486
Destination: 128/8, Local: 128.0.0.6, Broadcast: 128.255.255.255
Destination: 128/8, Local: 128.0.130.2, Broadcast: 128.255.255.255
Destination: 169.254/16, Local: 169.254.128.6, Broadcast: 169.254.255.255
Destination: 169.254/16, Local: 169.254.193.1, Broadcast: 169.254.255.255
Physical interface: IC-WS001:bme1, Enabled, Physical link is Up
Interface index: 49156, SNMP ifIndex: 1208483949
Type: Ethernet, Link-level type: Ethernet, MTU: 1514, Speed: 1000mbps
Device flags : Present Running
Interface flags: SNMP-Traps
Link type : Full-Duplex
Current address: 00:0d:0c:0f:00:03, Hardware address: 00:0d:0c:0f:00:03
Last flapped : 1970-01-01 00:00:01 UTC (2238w5d 22:25 ago)
Statistics last cleared: Never
Input packets : 168885
Output packets: 184712
Input errors: 0, Output errors: 0
Logical interface IC-WS001:bme1.0 (Index 3) (SNMP ifIndex 1208483950)
Flags: Encapsulation: ENET2
Input packets : 168885
Output packets: 184712
Protocol inet, MTU: 1500
Destination: 128/2, Local: 128.0.0.1, Broadcast: 191.255.255.255
Destination: 128/2, Local: 128.0.0.5, Broadcast: 191.255.255.255
Destination: 128/2, Local: 128.0.0.16, Broadcast: 191.255.255.255
Destination: 128/2, Local: 128.0.0.17, Broadcast: 191.255.255.255
Destination: 128/2, Local: 128.0.0.24, Broadcast: 191.255.255.255
Destination: 128/2, Local: 128.0.0.25, Broadcast: 191.255.255.255
Destination: 128/2, Local: 128.0.0.26, Broadcast: 191.255.255.255
Destination: 128/2, Local: 128.0.0.28, Broadcast: 191.255.255.255
Destination: 128/2, Local: 128.0.0.29, Broadcast: 191.255.255.255
Destination: 128/2, Local: 128.0.0.31, Broadcast: 191.255.255.255
Protocol tnp, MTU: 1500
Local: 0x5
Physical interface: IC-WS001:dcfabric, Enabled, Physical link is Up
Interface index: 27, SNMP ifIndex: 1208484093
Type: Ethernet, Link-level type: Ethernet, MTU: 1572
Device flags : Present Running
Interface flags: SNMP-Traps
Current address: 00:0b:ca:fe:00:01, Hardware address: 00:0b:ca:fe:00:01
Last flapped : Never
Statistics last cleared: Never
Input packets : 0
Output packets: 0
Input errors: 0, Output errors: 0
Logical interface IC-WS001:dcfabric.0 (Index 64) (SNMP ifIndex 1208484094)
Flags: SNMP-Traps Encapsulation: ENET2
Input packets : 0
Output packets: 0
Protocol inet, MTU: 1558
Protocol mpls, MTU: 1546, Maximum labels: 3
Protocol eth-switch, MTU: 0
Physical interface: IC-WS001:pme0, Enabled, Physical link is Up
Interface index: 66, SNMP ifIndex: 1208484104
Type: Ethernet, Link-level type: Ethernet, MTU: 1510, Speed: 1000mbps
Device flags : Present Running
Interface flags: SNMP-Traps
Link type : Full-Duplex
Current address: 00:23:9c:f1:a2:e6, Hardware address: 00:23:9c:f1:a2:e6
Last flapped : Never
Statistics last cleared: Never
Input packets : 1007238
Output packets: 63383
Input errors: 0, Output errors: 0
Physical interface: IC-WS001:pme1, Enabled, Physical link is Up
Interface index: 67, SNMP ifIndex: 1208484105
Type: Ethernet, Link-level type: Ethernet, MTU: 1510, Speed: 1000mbps
Device flags : Present Running
Interface flags: SNMP-Traps
Link type : Full-Duplex
Current address: 00:23:9c:f1:a2:e7, Hardware address: 00:23:9c:f1:a2:e7
Last flapped : Never
Statistics last cleared: Never
Input packets : 1007118
Output packets: 55381
Input errors: 0, Output errors: 0
Physical interface: IC-WS001:pme2, Enabled, Physical link is Down
Interface index: 68, SNMP ifIndex: 1208484106
Type: Ethernet, Link-level type: Ethernet, MTU: 1510, Speed: 1000mbps
Device flags : Present Running
Interface flags: SNMP-Traps
Link type : Full-Duplex
Current address: 00:23:9c:f1:a2:e8, Hardware address: 00:23:9c:f1:a2:e8
Last flapped : 2012-11-27 02:52:03 UTC (19:33:54 ago)
Statistics last cleared: Never
Input packets : 0
Output packets: 0
Input errors: 0, Output errors: 0
Physical interface: IC-WS001:pme3, Enabled, Physical link is Down
Interface index: 69, SNMP ifIndex: 1208484107
Type: Ethernet, Link-level type: Ethernet, MTU: 1510, Speed: 1000mbps
Device flags : Present Running
Interface flags: SNMP-Traps
Link type : Full-Duplex
Current address: 00:23:9c:f1:a2:e9, Hardware address: 00:23:9c:f1:a2:e9
Last flapped : 2012-11-27 02:52:03 UTC (19:33:54 ago)
Statistics last cleared: Never
Input packets : 0
Output packets: 0
Input errors: 0, Output errors: 0
Physical interface: IC-WS001:vcp0, Enabled, Physical link is Up
Interface index: 74, SNMP ifIndex: 1208484372
Type: Ethernet, Link-level type: 70, MTU: 1514, Speed: 1000mbps
Device flags : Present Running
Link type : Full-Duplex
Current address: 00:23:9c:f1:a2:e3, Hardware address: 00:23:9c:f1:a2:e3
Last flapped : Never
Statistics last cleared: Never
Input packets : 121842
Output packets: 3548
Input errors: 0, Output errors: 0
Logical interface IC-WS001:vcp0.32769 (Index 11) (SNMP ifIndex 1208484376)
Flags: LinkAddress 0-0 Encapsulation: ENET2
Input packets : 13044
Output packets: 3548
Physical interface: IC-WS001:vcp1, Enabled, Physical link is Up
Interface index: 70, SNMP ifIndex: 1208484108
Type: Ethernet, Link-level type: 70, MTU: 1492, Speed: 1000mbps
Device flags : Present Running
Link type : Full-Duplex
Current address: 00:23:9c:f1:a2:e6, Hardware address: 00:23:9c:f1:a2:e6
Last flapped : Never
Statistics last cleared: Never
Input packets : 767413
Output packets: 46503
Input errors: 0, Output errors: 0
Logical interface IC-WS001:vcp1.32768 (Index 7) (SNMP ifIndex 1208484109)
Flags: LinkAddress 0-0 Encapsulation: ENET2
Input packets : 735889
Output packets: 46503
Physical interface: IC-WS001:vcp2, Enabled, Physical link is Up
Interface index: 71, SNMP ifIndex: 1208484369
Type: Ethernet, Link-level type: 70, MTU: 1492, Speed: 1000mbps
Device flags : Present Running
Link type : Full-Duplex
Current address: 00:23:9c:f1:a2:e7, Hardware address: 00:23:9c:f1:a2:e7
Last flapped : Never
Statistics last cleared: Never
Input packets : 831710
Output packets: 44548
Input errors: 0, Output errors: 0
Logical interface IC-WS001:vcp2.32768 (Index 8) (SNMP ifIndex 1208484373)
Flags: LinkAddress 0-0 Encapsulation: ENET2
Input packets : 737844
Output packets: 44548
Physical interface: IC-WS001:vcp3, Enabled, Physical link is Down
Interface index: 72, SNMP ifIndex: 1208484370
Type: Ethernet, Link-level type: 70, MTU: 1492, Speed: 1000mbps
Device flags : Present Running
Link type : Full-Duplex
Current address: 00:23:9c:f1:a2:e8, Hardware address: 00:23:9c:f1:a2:e8
Last flapped : 2012-11-27 20:31:36 UTC (01:54:21 ago)
Statistics last cleared: Never
Input packets : 0
Output packets: 0
Input errors: 0, Output errors: 0
Logical interface IC-WS001:vcp3.32768 (Index 9) (SNMP ifIndex 1208484374)
Flags: LinkAddress 0-0 Encapsulation: ENET2
Input packets : 0
Output packets: 0
Physical interface: IC-WS001:vcp4, Enabled, Physical link is Down
Interface index: 73, SNMP ifIndex: 1208484371
Type: Ethernet, Link-level type: 70, MTU: 1492, Speed: 1000mbps
Device flags : Present Running
Link type : Full-Duplex
Current address: 00:23:9c:f1:a2:e9, Hardware address: 00:23:9c:f1:a2:e9
Last flapped : 2012-11-27 20:31:36 UTC (01:54:21 ago)
Statistics last cleared: Never
Input packets : 0
Output packets: 0
Input errors: 0, Output errors: 0
Logical interface IC-WS001:vcp4.32768 (Index 10) (SNMP ifIndex 1208484375)
Flags: LinkAddress 0-0 Encapsulation: ENET2
Input packets : 0
Output packets: 0show interfaces statistics fabric brief
user@switch> show interfaces statistics fabric brief
Physical interface: IC-WS001:fte-0/0/0, Enabled, Physical link is Down
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
Logical interface IC-WS001:fte-0/0/0.32768
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
eth-switch
Physical interface: IC-WS001:fte-0/0/4, Enabled, Physical link is Down
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
Logical interface IC-WS001:fte-0/0/4.32768
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
eth-switch
Physical interface: IC-WS001:fte-0/0/6, Enabled, Physical link is Down
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
Logical interface IC-WS001:fte-0/0/6.32768
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
eth-switch
Physical interface: IC-WS001:fte-0/0/13, Enabled, Physical link is Down
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
Logical interface IC-WS001:fte-0/0/13.32768
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
eth-switch
Physical interface: IC-WS001:fte-0/0/15, Enabled, Physical link is Down
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
Logical interface IC-WS001:fte-0/0/15.32768
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
eth-switch
Physical interface: IC-WS001:fte-1/0/2, Enabled, Physical link is Down
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
Logical interface IC-WS001:fte-1/0/2.32768
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
eth-switch
Physical interface: IC-WS001:fte-1/0/7, Enabled, Physical link is Down
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
Logical interface IC-WS001:fte-1/0/7.32768
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
eth-switch
Physical interface: IC-WS001:fte-1/0/10, Enabled, Physical link is Down
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
Logical interface IC-WS001:fte-1/0/10.32768
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
eth-switch
Physical interface: IC-WS001:bme0, Enabled, Physical link is Up
Type: Ethernet, Link-level type: Ethernet, MTU: 1500, Clocking: Unspecified, Speed: Unspecified
Device flags : Present Running
Logical interface IC-WS001:bme0.0
Flags: LinkAddress 0-0 Encapsulation: ENET2
inet 128.0.32.0 --> 0/0
Logical interface IC-WS001:bme0.1
Flags: LinkAddress 0-0 Encapsulation: ENET2
inet 128.0.0.6/2
128.0.130.2/2
Logical interface IC-WS001:bme0.2
Flags: Encapsulation: ENET2
inet 128.0.0.6/8
128.0.130.2/8
169.254.128.6/16
169.254.193.1/16
Physical interface: IC-WS001:bme1, Enabled, Physical link is Up
Type: Ethernet, Link-level type: Ethernet, MTU: 1514, Clocking: Unspecified, Speed: 1000mbps
Device flags : Present Running
Interface flags: SNMP-Traps
Logical interface IC-WS001:bme1.0
Flags: Encapsulation: ENET2
inet 128.0.0.1/2
128.0.0.5/2
128.0.0.16/2
128.0.0.17/2
128.0.0.24/2
128.0.0.25/2
128.0.0.26/2
128.0.0.28/2
128.0.0.29/2
128.0.0.31/2
tnp 0x5
Physical interface: IC-WS001:dcfabric, Enabled, Physical link is Up
Type: Ethernet, Link-level type: Ethernet, MTU: 1572, Clocking: Unspecified, Speed: Unspecified
Device flags : Present Running
Interface flags: SNMP-Traps
Logical interface IC-WS001:dcfabric.0
Flags: SNMP-Traps Encapsulation: ENET2
inet
mpls
eth-switch
Physical interface: IC-WS001:pme0, Enabled, Physical link is Up
Type: Ethernet, Link-level type: Ethernet, MTU: 1510, Clocking: Unspecified, Speed: 1000mbps
Device flags : Present Running
Interface flags: SNMP-Traps
Physical interface: IC-WS001:pme1, Enabled, Physical link is Up
Type: Ethernet, Link-level type: Ethernet, MTU: 1510, Clocking: Unspecified, Speed: 1000mbps
Device flags : Present Running
Interface flags: SNMP-Traps
Physical interface: IC-WS001:pme2, Enabled, Physical link is Down
Type: Ethernet, Link-level type: Ethernet, MTU: 1510, Clocking: Unspecified, Speed: 1000mbps
Device flags : Present Running
Interface flags: SNMP-Traps
Physical interface: IC-WS001:pme3, Enabled, Physical link is Down
Type: Ethernet, Link-level type: Ethernet, MTU: 1510, Clocking: Unspecified, Speed: 1000mbps
Device flags : Present Running
Interface flags: SNMP-Traps
Physical interface: IC-WS001:vcp0, Enabled, Physical link is Up
Type: Ethernet, Link-level type: 70, MTU: 1514, Clocking: Unspecified, Speed: 1000mbps
Device flags : Present Running
Logical interface IC-WS001:vcp0.32769
Flags: LinkAddress 0-0 Encapsulation: ENET2
Physical interface: IC-WS001:vcp1, Enabled, Physical link is Up
Type: Ethernet, Link-level type: 70, MTU: 1492, Clocking: Unspecified, Speed: 1000mbps
Device flags : Present Running
Logical interface IC-WS001:vcp1.32768
Flags: LinkAddress 0-0 Encapsulation: ENET2
Physical interface: IC-WS001:vcp2, Enabled, Physical link is Up
Type: Ethernet, Link-level type: 70, MTU: 1492, Clocking: Unspecified, Speed: 1000mbps
Device flags : Present Running
Logical interface IC-WS001:vcp2.32768
Flags: LinkAddress 0-0 Encapsulation: ENET2
Physical interface: IC-WS001:vcp3, Enabled, Physical link is Down
Type: Ethernet, Link-level type: 70, MTU: 1492, Clocking: Unspecified, Speed: 1000mbps
Device flags : Present Running
Logical interface IC-WS001:vcp3.32768
Flags: Device-Down LinkAddress 0-0 Encapsulation: ENET2
Physical interface: IC-WS001:vcp4, Enabled, Physical link is Down
Type: Ethernet, Link-level type: 70, MTU: 1492, Clocking: Unspecified, Speed: 1000mbps
Device flags : Present Running
Logical interface IC-WS001:vcp4.32768
Flags: Device-Down LinkAddress 0-0 Encapsulation: ENET2show interfaces statistics fabric detail
user@switch> show interfaces statistics fabric detail
show interfaces statistics fabric detail
Physical interface: IC-WS001:fte-0/0/0, Enabled, Physical link is Down
Interface index: 49174, SNMP ifIndex: 1208484473, Generation: 153
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
CoS queues : 12 supported, 12 maximum usable queues
Hold-times : Up 0 ms, Down 0 ms
Current address: 00:00:00:00:00:00, Hardware address: 00:00:00:00:00:00
Last flapped : 2012-11-27 20:30:30 UTC (02:04:59 ago)
Statistics last cleared: Never
Traffic statistics:
Input bytes : 0 0 bps
Output bytes : 0 0 bps
Input packets: 0 0 pps
Output packets: 0 0 pps
IPv6 transit statistics:
Input bytes : 0
Output bytes : 0
Input packets: 0
Output packets: 0
Input errors:
Errors: 0, Drops: 0, Framing errors: 0, Runts: 0, Policed discards: 0, L3 incompletes: 0, L2 channel errors: 0, L2 mismatch timeouts: 0, FIFO errors: 0, Resource errors: 0
Output errors:
Carrier transitions: 0, Errors: 0, Drops: 0, Collisions: 0, Aged packets: 0, FIFO errors: 0, HS link CRC errors: 0, MTU errors: 0, Resource errors: 0
Egress queues: 12 supported, 5 in use
Queue counters: Queued packets Transmitted packets Dropped packets
0 fabric_fcset 0 0 0
1 fabric_fcset 0 0 0
2 fabric_fcset 0 0 0
3 fabric_fcset 0 0 0
4 fabric_fcset 0 0 0
5 fabric_fcset 0 0 0
6 fabric_fcset 0 0 0
7 fabric_fcset 0 0 0
8 fabric_fcset 0 0 0
9 fabric_fcset 0 0 0
10 fabric_fcset 0 0 0
11 fabric_fcset 0 0 0
Logical interface IC-WS001:fte-0/0/0.32768 (Index 83) (SNMP ifIndex 1208484474) (Generation 148)
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Traffic statistics:
Input bytes : 0
Output bytes : 0
Input packets: 0
Output packets: 0
Local statistics:
Input bytes : 0
Output bytes : 0
Input packets: 0
Output packets: 0
Transit statistics:
Input bytes : 0 0 bps
Output bytes : 0 0 bps
Input packets: 0 0 pps
Output packets: 0 0 pps
Protocol eth-switch, MTU: 0, Generation: 176, Route table: 0
show interfaces statistics fabric terse
user@switch> show interfaces statistics fabric terse
Interface Admin Link Proto Local Remote
IC-WS001:fte-0/0/0 up down
IC-WS001:fte-0/0/0.32768 up down eth-switch
IC-WS001:fte-0/0/4 up down
IC-WS001:fte-0/0/4.32768 up down eth-switch
IC-WS001:fte-0/0/6 up down
IC-WS001:fte-0/0/6.32768 up down eth-switch
IC-WS001:fte-0/0/13 up down
IC-WS001:fte-0/0/13.32768 up down eth-switch
IC-WS001:fte-0/0/15 up down
IC-WS001:fte-0/0/15.32768 up down eth-switch
IC-WS001:fte-1/0/2 up down
IC-WS001:fte-1/0/2.32768 up down eth-switch
IC-WS001:fte-1/0/7 up down
IC-WS001:fte-1/0/7.32768 up down eth-switch
IC-WS001:fte-1/0/10 up down
IC-WS001:fte-1/0/10.32768 up down eth-switch
IC-WS001:bme0 up up
IC-WS001:bme0.0 up up inet 128.0.32.0 --> 0/0
IC-WS001:bme0.1 up up inet 128.0.0.6/2
128.0.130.2/2
IC-WS001:bme0.2 up up inet 128.0.0.6/8
128.0.130.2/8
169.254.128.6/16
169.254.193.1/16
IC-WS001:bme1 up up
IC-WS001:bme1.0 up up inet 128.0.0.1/2
128.0.0.5/2
128.0.0.16/2
128.0.0.17/2
128.0.0.24/2
128.0.0.25/2
128.0.0.26/2
128.0.0.28/2
128.0.0.29/2
128.0.0.31/2
tnp 0x5
IC-WS001:dcfabric up up
IC-WS001:dcfabric.0 up up inet
mpls
eth-switch
IC-WS001:pme0 up up
IC-WS001:pme1 up up
IC-WS001:pme2 up down
IC-WS001:pme3 up down
IC-WS001:vcp0 up up
IC-WS001:vcp0.32769 up up
IC-WS001:vcp1 up up
IC-WS001:vcp1.32768 up up
IC-WS001:vcp2 up up
IC-WS001:vcp2.32768 up up
IC-WS001:vcp3 up down
IC-WS001:vcp3.32768 up down
IC-WS001:vcp4 up down
IC-WS001:vcp4.32768 up downshow interfaces statistics fabric device-name
user@switch> show interfaces statistics fabric IC-WS001:fte-0/0/13
Physical interface: IC-WS001:fte-0/0/13, Enabled, Physical link is Down
Interface index: 49177, SNMP ifIndex: 1208484479
Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x0
CoS queues : 12 supported, 12 maximum usable queues
Current address: 00:00:00:00:00:0d, Hardware address: 00:00:00:00:00:0d
Last flapped : 2012-11-27 20:30:30 UTC (02:09:53 ago)
Statistics last cleared: Never
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
Input errors: 0, Output errors: 0
Logical interface IC-WS001:fte-0/0/13.32768 (Index 86) (SNMP ifIndex 1208484480)
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Input packets : 0
Output packets: 0
Protocol eth-switch, MTU: 0Release Information
Command introduced in Junos OS Release 12.3.