show chassis fpc optical-properties amplifier-chain ila summary
Syntax
show chassis fpc optical-properties amplifier-chain ila summary fpc-slot fpc-slot ila-number ila-number
Description
Display detailed information for the optical inline amplifier (ILA) such as the manufacturing details, power and temperature information, fan information, and so on.
Options
| fpc-slot |
Slot number of the FPC or PIC in which the integrated photonic line card (IPLC) module resides. |
| ila-number |
The number assigned to the optical ILA. |
Required Privilege Level
view
Output Fields
Table 1 lists the output fields for the show chassis fpc optical-properties amplifier-chain ila summary command. Output fields are listed in the approximate order in which they appear.
| Field Name | Field Description |
|---|---|
| ILA Number | Number assigned to the optical ILA. |
| ILA Name | Name of the optical ILA. |
| ILA Position | Position of the optical ILA in the amplifier chain. This value can change if optical ILAs are added or removed from the amplifier chain. |
| OSC IP Address | Displays the configured IP address of the optical ILA used for optical supervisory channel (OSC) communications with the anchor IPLC module in the PTX3000 integrated photonic line system. The IP address must be on the same, private subnet as the anchor IPLC. |
| Manufacture Name | Name of manufacturer. |
| Manufacture Date | Date of manufacture. |
| Part Number | Part number of the optical ILA. |
| Serial Num | Serial number of the optical ILA. |
| Calibration Date | Date of calibrating the components such as; pumps, optical power, and so on. |
| Firmware version | Firmware version number. |
| Hardware Version | Hardware version number. |
| FPGA Version | Field-programmable gate array (FPGA) version number. |
| X86CPLD Version | X86CPLD processor version number. |
| Board CPLD Version | Board CPLD version number. |
| System Date and System Time | System time and date. |
| Up Time | Time the device has been up. |
| IP v4 Address/Mask/Gateway | IPv4 address for the optical ILA interface. |
| OSC MAC Address | MAC address of the associated IPLC OSC management interface. |
| Board Temperature (C) | Temperature of the main board. |
| Temperature Threshold High/Low (C) | Temperature at which an alarm is raised when it is too high or it is too low. |
| Power and Fan Plug Status (Fan 0/1/2, Power 0/1) | Displays how many power supplies and fans are plugged in. |
| Fan Speed (Fan 0/1/2) | Fan speed. |
| System Mode (auto/manual) | System mode: auto or manual. The auto mode is the default. The manual mode is available only for debug purposes. |
| Firmware Upgrade Status (none/in progress/done) | Firmware upgrade status. |
Sample Output
show chassis fpc optical-properties amplifier-chain ila summary
user@host> show chassis fpc optical-properties amplifier-chain ila summary fpc-slot 3 ila-number 0
ILA Number 0 ILA Name ILA-0 ILA Position 1 OSC IP Address 10.0.0.11/255.255.255.0 Manufacture Name oplk Manufacture Date 2016-04-07 Part Number EDFA128ILAJUP01 Serial Num 3D2L6140001 Calibration Date 2016-04-07 Firmware Version 2.10.0001 Hardware Version 2.01 FPGA Version 5.0 X86CPLD Version 28 Board CPLD Version 41 System Date 2015-10-04 System Time 02:00:19 GMT-0700 Up Time 2255845 IP v4 Address/Mask/Gateway 192.168.7.135/255.255.0.0/ 192.168.7.254 OSC MAC Address aa:bb:cc:dd:ee:01 Board Temperature (C) 31.4 Temperature Threshold High/Low (C) 55.0/-5.0 Power and Fan Plug Status (Fan 0/1/2, Power 0/1) Fan0: 1 Fan1: 1 Fan2: 1 Power0: 0 Power1: 1 Fan Speed (Fan 0/1/2) 9984 / 9984 / 10752 System Mode (auto/manual) Auto Firmware Upgrade Status (none/in progress/done) Status: Successful Percent: 0
Release Information