show chassis fpc optical-properties alarms
Syntax
show chassis fpc optical-properties alarms fpc-slot fpc-slot
Description
Display the alarms for the integrated photonic line card (IPLC) module installed in the Flexible PIC Concentrator (FPC) or PIC slot. Use this command to view the current alarms on the IPLC.
Options
| fpc-slot |
Slot number of the FPC or PIC in which the IPLC module resides. |
Additional Information
The alarms provide information about system or component failures on the IPLC.
The fpc-slot number in the alarms refers to the FPC or PIC in which the IPLC module resides.
| Alarm | Description |
|---|---|
| IPLC fpc-slot AWG Add LOS | The IPLC AWG Add port has detected loss of signal (LOS). |
| IPLC fpc-slot Express-In LOS | The IPLC Express-In (XPN-IN) port has detected LOS. |
| IPLC fpc-slot OSC Add LOS | The IPLC OSC Add port has detected LOS. |
| IPLC fpc-slot OSC Drop LOS | The IPLC OSC Drop port has detected LOS. |
| IPLC fpc-slot Line In LOS | The IPLC Line IN port has detected LOS. |
| IPLC fpc-slot Reflect Power Failure | The IPLC has detected back reflection power failure. |
| IPLC fpc-slot Out of Gain | The IPLC could not converge on the set gain. It is operating at a gain value exceeding the allowable deviation from the set gain. |
| IPLC fpc-slot Pump EOL | The IPLC pump has reached its end of life (i.e. Pump current has reached the maximum rated value). |
| IPLC fpc-slot Temperature Failure | The IPLC EDFA has detected temperature failure. |
| IPLC fpc-slot Output LOS | The IPLC EDFA Output port has detected LOS. |
| IPLC fpc-slot Input LOS | The IPLC EDFA Input port has detected LOS. |
| IPLC fpc-slot Output Power Failure | The IPLC Output port has detected power failure. |
| IPLC fpc-slot WSS Temperature Failure | The IPLC WSS has detected temperature failure. |
| IPLC fpc-slot Inter Diag | The IPLC is in the diagnostics mode. |
| IPLC fpc-slot Firmware Inconsistent |
The IPLC firmware is inconsistent with the software or hardware. Note:
If you see this alarm, upgrade your firmware by using the request chassis fpc optical-module firmware-upgrade command. |
| IPLC fpc-slot OCM Module Failure | The IPLC OCM module has failed. |
| IPLC fpc-slot WSS Module Failure | The IPLC WSS module has failed. |
| IPLC fpc-slot EDFA2 Module Failure | The IPLC EDFA2 module has failed. |
| IPLC fpc-slot EDFA1 Module Failure | The IPLC EDFA1 module has failed. |
| IPLC fpc-slot SFP LOS | The IPLC SFP has detected LOS. |
| IPLC fpc-slot SFP LOF | The IPLC SFP has detected loss of frame (LOF). |
Required Privilege Level
view
Output Fields
| Field Name | Field Description |
|---|---|
| Module | Component on which the alarm is triggered. |
| Active | FPC or PIC slot number where the active alarm is triggered. |
| Alarms | Alarm that is triggered. |
Sample Output
show chassis fpc optical-properties alarms
user@host> show chassis fpc optical-properties alarms fpc-slot 14
Module Active Alarms Main Board IPLC 14 OSC Drop LOS Main Board IPLC 14 Line In LOS Output EDFA IPLC 14 Output LOS Output EDFA IPLC 14 Input LOS Main Board IPLC 14 Firmware Inconsistent Main Board IPLC 14 SFP LOS
Release Information
Statement introduced in Junos OS Release 15.1F6 and 17.1R1.