show chassis fpc global pfe-id
Syntax
show chassis fpc global pfe-id
Description
Display the global pfe-id. The devices supported are MX10004, MX10008, MX10016, MX2010, and MX2020. The outputs are independent of the line card and the status of the FPC or PFE. This output is based on the chassis and the fabric card.
Additional Information
The output is displayed independent of the line card and the status of the FPC or PFE. This output is based on the chassis and the fabric card.
Required Privilege Level
view
Output Fields
Table 1 lists
the output fields for the show chassis fpc global pfe-id command.
|
Field Name |
Field Description |
|---|---|
|
FPC |
FPC slot number of the Flexible PIC Concentrator (FPC). |
|
Global PFE ID |
Unique Identifier for a PFE in a chassis. Local PFE ID = Unique identifier for a PFE in an FPC. |
Sample Output
- show chassis fpc global pfe-id (MX10008 )
- show chassis fpc global pfe-id (MX10004)
- show chassis fpc global pfe-id (MX2020 Routers)
- show chassis fpc global pfe-id (MX2010 Routers)
show chassis fpc global pfe-id (MX10008 )
user@host> show chassis fpc global pfe-id
FPC Global PFE ID
PFE0 PFE1 PFE2 PFE3 PFE4 PFE5 PFE6 PFE7 PFE8 PFE9 PFE10 PFE11 PFE12 PFE13 PFE14 PFE15
----------------------------------------------------------------------------------------------------------
0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
2 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
3 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
4 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79
5 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95
6 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111
7 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
----------------------------------------------------------------------------------------------------------
show chassis fpc global pfe-id (MX10004)
user@host> show chassis fpc global-pfe-id ---------------------------------------------------------------------------------------------------------- FPC Global PFE ID PFE0 PFE1 PFE2 PFE3 PFE4 PFE5 PFE6 PFE7 PFE8 PFE9 PFE10 PFE11 PFE12 PFE13 PFE14 PFE15 ---------------------------------------------------------------------------------------------------------- 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 2 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 3 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 ----------------------------------------------------------------------------------------------------------
show chassis fpc global pfe-id (MX2020 Routers)
user@host> show chassis fpc global pfe-id
FPC Global PFE ID
PFE0 PFE1 PFE2 PFE3 PFE4 PFE5 PFE6 PFE7
----------------------------------------------------------
0 0 1 2 3 80 81 82 83
1 4 5 6 7 84 85 86 87
2 8 9 10 11 88 89 90 91
3 12 13 14 15 92 93 94 95
4 16 17 18 19 96 97 98 99
5 20 21 22 23 100 101 102 103
6 24 25 26 27 104 105 106 107
7 28 29 30 31 108 109 110 111
8 32 33 34 35 112 113 114 115
9 36 37 38 39 116 117 118 119
10 40 41 42 43 120 121 122 123
11 44 45 46 47 124 125 126 127
12 48 49 50 51 128 129 130 131
13 52 53 54 55 132 133 134 135
14 56 57 58 59 136 137 138 139
15 60 61 62 63 140 141 142 143
16 64 65 66 67 144 145 146 147
17 68 69 70 71 148 149 150 151
18 72 73 74 75 152 153 154 155
19 76 77 78 79 156 157 158 159
----------------------------------------------------------
show chassis fpc global pfe-id (MX2010 Routers)
user@host> show chassis fpc global pfe-id
FPC Global PFE ID
PFE0 PFE1 PFE2 PFE3 PFE4 PFE5 PFE6 PFE7
----------------------------------------------------------
0 0 1 2 3 80 81 82 83
1 4 5 6 7 84 85 86 87
2 8 9 10 11 88 89 90 91
3 12 13 14 15 92 93 94 95
4 16 17 18 19 96 97 98 99
5 20 21 22 23 100 101 102 103
6 24 25 26 27 104 105 106 107
7 28 29 30 31 108 109 110 111
8 32 33 34 35 112 113 114 115
9 36 37 38 39 116 117 118 119
----------------------------------------------------------
Release Information
Command introduced in Junos OS Release 21.4R1.