show chassis fabric sibs
Syntax
show chassis fabric sibs <extended> <slot slot-number>
Description
(M320, PTX Series routers and QFX Series switches) Display the state of the electrical switch fabric link between the SIBs and the FPCs.
Options
| none |
(M320 PTX Series routers and QFX Series switches) Display the state of the electrical switch fabric link between the SIBs and the FPCs. |
| extended |
(Optional) Show all planes in output |
| slot slot-number |
(Optional) Display the state of the electrical switch fabric link between the specified SIB slot and the FPCs. |
Required Privilege Level
view
Output Fields
Table 1 lists the output fields for the show chassis fabric
sibs command. Output fields are listed in the approximate
order in which they appear.
Field Name |
Field Description |
|---|---|
|
Switching fabric link (link from FPC to SIB) state for each SIB:
|
|
Possible plane state of the M320 SIB:
|
Sample Output
- show chassis fabric sibs (M320 Router)
- show chassis fabric sibs slot (Junos OS Evolved PTX10008 and PTX10016)
- show chassis fabric sibs (PTX10008 Router)
- show chassis fabric sibs extended (PTX10008 Router with LC1201 Line Card)
- show chassis fabric sibs extended (PTX10008 Router with PTX10K-LC1301-36DD Line Card)
- show chassis fabric sibs (QFX10008 Switch)
show chassis fabric sibs (M320 Router)
user@host> show chassis fabric sibs
Fabric management SIB state:
SIB #0
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok
SIB #1
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok
SIB #2
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok
SIB #3
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok show chassis fabric sibs slot (Junos OS Evolved PTX10008 and PTX10016)
The output of the show chassis fabric sibs command is modified
to include ASIC information. In the earlier releases, this command displayed
ASICs as FCOREs. With this modification, for every FPC and SIB, information
about ASIC and FCORE is presented separately in the output.
Each fabric
chip hosts 2 planes (plane 0, 1) in PTX10008. Each fabric chip hosts a single
plane (plane 0) in PTX10016.
PTX10008 supports 0-7 FPCs. PTX10016 supports 0-15 FPCs.
user@host> show chassis fabric sibs slot 0
Fabric management SIB state:
SIB #0 Online
Asic #0 Fcore #0 (plane 0) Empty
FPC #0
PFE #0 : Links ok
PFE #1 : Links ok
PFE #2 : Links ok
PFE #3 : Links okshow chassis fabric sibs (PTX10008 Router)
user@host> show chassis fabric sibs
Fabric management SIB state:
SIB #0 Online
FASIC #0 (plane 0) Active
FPC #0
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
FPC #5
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
FPC #6
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
FASIC #1 (plane 1) Active
FPC #0
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
FPC #5
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
FPC #6
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
SIB #1 Online
FASIC #0 (plane 2) Active
FPC #0
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
FPC #5
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
FPC #6
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
FASIC #1 (plane 3) Active
FPC #0
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
FPC #5
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
FPC #6
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
SIB #2 Empty
SIB #3 Empty
SIB #4 Empty
SIB #5 Empty
show chassis fabric sibs extended (PTX10008 Router with LC1201 Line Card)
user@host> show chassis fabric sibs extended
Fabric management SIB state:
SIB #0 Online
Asic #0 Fcore #0 (plane 0) Active
FPC #0
PFE #0 : Links ok FPC00FE0(2,06)->S00F0_0(45,0,45)
PFE #1 : Links ok FPC00FE1(0,05)->S00F0_0(46,0,46)
PFE #2 : Links ok FPC00FE2(3,06)->S00F0_0(42,3,42)
PFE #3 : Links ok FPC00FE3(0,05)->S00F0_0(44,2,44)
PFE #4 : Links ok FPC00FE4(2,03)->S00F0_0(43,3,43)
PFE #5 : Links ok FPC00FE5(0,04)->S00F0_0(42,2,42)
PFE #6 : Links ok FPC00FE6(0,08)->S00F0_0(43,2,43)
PFE #7 : Links ok FPC00FE7(1,01)->S00F0_0(42,1,42)
PFE #8 : Links ok FPC00FE8(2,08)->S00F0_0(45,1,45)
FPC #1
PFE #0 : Links ok FPC01FE0(2,06)->S00F0_0(35,0,35)
PFE #1 : Links ok FPC01FE1(0,05)->S00F0_0(33,2,33)
PFE #2 : Links ok FPC01FE2(3,06)->S00F0_0(47,2,47)
...
show chassis fabric sibs extended (PTX10008 Router with PTX10K-LC1301-36DD Line Card)
user@host> show chassis fabric sibs extended
Fabric management SIB state:
SIB #0 Offline
SIB #1 Offline
SIB #2 Online
Asic #0 Fcore #0 (plane 6) Active
FPC #1
PFE #0 : Links ok FPC01FE0(5,08)->SIB02F0(6,00)
PFE #0 : Links ok FPC01FE0(5,07)->SIB02F0(6,01)
PFE #0 : Links ok FPC01FE0(6,04)->SIB02F0(5,07)
PFE #0 : Links ok FPC01FE0(6,08)->SIB02F0(6,02)
PFE #0 : Links ok FPC01FE0(8,06)->SIB02F0(6,05)
PFE #1 : Links ok FPC01FE1(0,02)->SIB02F0(5,03)
PFE #1 : Links ok FPC01FE1(0,00)->SIB02F0(5,04)
PFE #1 : Links ok FPC01FE1(5,03)->SIB02F0(4,06)
PFE #1 : Links ok FPC01FE1(4,08)->SIB02F0(5,01)
PFE #2 : Links ok FPC01FE2(6,02)->SIB02F0(5,06)
PFE #2 : Links ok FPC01FE2(6,07)->SIB02F0(5,05)
PFE #2 : Links ok FPC01FE2(1,05)->SIB02F0(4,02)
PFE #2 : Links ok FPC01FE2(1,07)->SIB02F0(4,05)
PFE #2 : Links ok FPC01FE2(8,06)->SIB02F0(5,02)
PFE #3 : Links ok FPC01FE3(7,07)->SIB02F0(4,03)
PFE #3 : Links ok FPC01FE3(7,04)->SIB02F0(5,00)
PFE #3 : Links ok FPC01FE3(4,07)->SIB02F0(4,04)
PFE #3 : Links ok FPC01FE3(4,02)->SIB02F0(4,07)
FPC #2
PFE #0 : Links ok FPC02FE0(5,08)->SIB02F0(8,01)
PFE #0 : Links ok FPC02FE0(5,07)->SIB02F0(8,04)
PFE #0 : Links ok FPC02FE0(6,04)->SIB02F0(8,02)
PFE #0 : Links ok FPC02FE0(6,08)->SIB02F0(8,05)
PFE #0 : Links ok FPC02FE0(8,06)->SIB02F0(8,03)
PFE #1 : Links ok FPC02FE1(0,02)->SIB02F0(7,04)
PFE #1 : Links ok FPC02FE1(0,00)->SIB02F0(8,00)
...
On a PTX10008 device with PTX10K-LC1301-36DD line card, each plane contains multiple links.
show chassis fabric sibs (QFX10008 Switch)
user@host> show chassis fabric sibs
Fabric management SIB state:
SIB #0 Online
FASIC #0 (plane 0) Active
FPC #0
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
FPC #1
PFE #0 : OK
PFE #1 : OK
FASIC #1 (plane 1) Active
FPC #0
PFE #0 : OK
PFE #1 : OK
FPC #12
PFE #0 : OK
PFE #1 : OK
SIB #1 Empty
SIB #2 Empty
SIB #3 Empty
SIB #4 Empty
SIB #5 Empty Release Information
Command introduced before Junos OS Release 7.4.
Command introduced on QFX Series switches in Junos OS Release 15.1X53-D30