show chassis fabric sibs
Syntax
show chassis fabric sibs <lcc number | scc> <slot slot-number>
Description
(TX Matrix routers only) Display the state of the electrical and optical switch fabric link between the SIBs in the TX Matrix router (TX-SIBs) and the SIBs in the T640 routers (T640 LCC SIBs).
(M320, T640, T1600, T4000 and PTX Series routers and QFX Series switches) Display the state of the electrical switch fabric link between the SIBs and the FPCs.
Options
| none | (TX Matrix routers only) Display the state of the electrical and optical switch fabric link between the SIBs in the TX Matrix router (TX-SIBs) and the SIBs in the T640 routers (T640 LCC SIBs). (M320, T640, T1600, T4000 and PTX Series routers and QFX Series switches) Display the state of the electrical switch fabric link between the SIBs and the FPCs. |
| lcc number | (Optional) Display the switching fabric link state for the T640 SIBs on a specified T640 router (line-card chassis) connected to a TX Matrix router. |
| scc | (Optional) Display the switching fabric link state for the TX-SIBs on the TX Matrix router (switch-card chassis). |
| slot slot-number | (Optional) Display the state of the electrical switch fabric link between the specified SIB slot and the FPCs. |
Required Privilege Level
view
Output Fields
Table 1 lists the output fields for the show chassis fabric
sibs command. Output fields are listed in the approximate
order in which they appear.
Field Name |
Field Description |
|---|---|
|
Switching fabric link (link from FPC to SIB) state for each SIB:
|
|
Possible plane state of the M320 SIB, TX-SIB or T640 SIB:
|
Sample Output
- show chassis fabric sibs (M320 Router)
- show chassis fabric sibs (T640 Router)
- show chassis fabric sibs (T1600 Router)
- show chassis fabric sibs (T4000 Core Router)
- show chassis fabric sibs (TX Matrix Router)
- show chassis fabric sibs lcc (TX Matrix Router)
- show chassis fabric sibs scc (TX Matrix Router)
- show chassis fabric sibs slot (PTX3000 Router)
- show chassis fabric sibs slot (Junos OS Evolved PTX10008 and PTX10016)
- show chassis fabric sibs (PTX10008 Router)
- show chassis fabric sibs (QFX10008 Switch)
show chassis fabric sibs (M320 Router)
user@host> show chassis fabric sibs
Fabric management SIB state:
SIB #0
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok
SIB #1
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok
SIB #2
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok
SIB #3
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok show chassis fabric sibs (T640 Router)
user@host> show chassis fabric sibs
Fabric management SIB state:
SIB #0
plane state: S_SPARE
FPC #0
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #0 : Links ok
PFE #1 : Links ok
SIB #1
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #0 : Links ok
PFE #1 : Links ok
SIB #2
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #0 : Links ok
PFE #1 : Links ok
SIB #3
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #0 : Links ok
PFE #1 : Links ok
SIB #4
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #2
PFE #1 : Links ok
FPC #3
PFE #0 : Links ok
PFE #1 : Links ok show chassis fabric sibs (T1600 Router)
user@host> show chassis fabric sibs
SIB #0
plane state: S_SPARE
FPC #0
PFE #0 : Links ok
PFE #1 : Links ok
FPC #1
PFE #0 : Links ok
PFE #1 : Links ok
FPC #2
PFE #0 : Links ok
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #5
PFE #0 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
SIB #1
plane state: S_ACTIVE , plane has link errors on 2 pfes
FPC #0
PFE #0 : Links ok
PFE #1 : Links ok
FPC #1
PFE #0 : Links ok
PFE #1 : Links ok
FPC #3
PFE #0 : Links ok
PFE #1 : Links ok
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #5
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links okSIB #2
plane state: S_ACTIVE
SIB #2
plane state: S_ACTIVE
FPC #0
PFE #0 : Links ok
PFE #1 : Links ok
FPC #1
PFE #0 : Links ok
PFE #1 : Links ok
FPC #2
PFE #0 : Links ok
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #5
PFE #0 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
SIB #3
plane state: S_ACTIVE
FPC #0
PFE #0 : Links ok
PFE #1 : Links ok
FPC #1
PFE #0 : Links ok
PFE #1 : Links ok
FPC #2
PFE #0 : Links ok
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #5
PFE #0 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
SIB #4
plane state: S_ACTIVE
FPC #0
PFE #0 : Links ok
PFE #1 : Links ok
FPC #1
PFE #0 : Links ok
PFE #1 : Links ok
FPC #2
PFE #0 : Links ok
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #5
PFE #0 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
show chassis fabric sibs (T4000 Core Router)
user@host> show chassis fabric sibs
Fabric management SIB state:
SIB #0
plane state: S_SPARE
FPC #2
PFE #0 : Links ok
FPC #3
PFE #0 : Links ok
FPC #5
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
SIB #1
plane state: S_ACTIVE
FPC #2
PFE #0 : Links ok
FPC #3
PFE #0 : Links ok
FPC #5
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
SIB #2
plane state: S_ACTIVE
FPC #2
PFE #0 : Links ok
FPC #3
PFE #0 : Links ok
FPC #5
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
SIB #3
plane state: S_ACTIVE
FPC #2
PFE #0 : Links ok
FPC #3
PFE #0 : Links ok
FPC #5
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
SIB #4
plane state: S_ACTIVE
FPC #2
PFE #0 : Links ok
FPC #3
PFE #0 : Links ok
FPC #5
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok show chassis fabric sibs (TX Matrix Router)
user@host> show chassis fabric sibs
scc-re0:
--------------------------------------------------------------------------
Fabric management SIB state:
SIB #1
plane state: S_ACTIVE , plane has link errors on 2 pfes
FPC #0
PFE #0 : Links ok
PFE #1 : Links ok
FPC #1
PFE #0 : Links ok
PFE #1 : Links ok
FPC #3
PFE #0 : Links ok
PFE #1 : Links ok
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #5
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
SIB #2
plane state: S_ACTIVE
LCC #0 : Links ok
LCC #1 : Links ok
SIB #3
plane state: S_ACTIVE
LCC #0 : Links ok
LCC #1 : Links ok
SIB #4
plane state: S_ACTIVE
LCC #0 : Links ok
LCC #1 : Links ok
lcc0-re0:
--------------------------------------------------------------------------
Fabric management SIB state:
SIB #1
plane state: S_ACTIVE
FPC #0
PFE #0 : Links ok
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #0 : Links ok
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok
FPC #4
PFE #1 : Links ok
FPC #5
PFE #0 : Links ok
FPC #6
PFE #1 : Links ok
FPC #7
PFE #1 : Links ok
SCC : Links ok
SIB #2
plane state: S_ACTIVE
FPC #0
PFE #0 : Links ok
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #0 : Links ok
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok
FPC #4
PFE #1 : Links ok
FPC #5
PFE #0 : Links ok
FPC #6
PFE #1 : Links ok
FPC #7
PFE #1 : Links ok
SCC : Links ok
SIB #3
plane state: S_ACTIVE
FPC #0
PFE #0 : Links ok
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #0 : Links ok
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok
FPC #4
PFE #1 : Links ok
FPC #5
PFE #0 : Links ok
FPC #6
PFE #1 : Links ok
FPC #7
PFE #1 : Links ok
SCC : Links ok
SIB #4
plane state: S_ACTIVE
FPC #0
PFE #0 : Links ok
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #0 : Links ok
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok
FPC #4
PFE #1 : Links ok
FPC #5
PFE #0 : Links ok
FPC #6
PFE #1 : Links ok
FPC #7
PFE #1 : Links ok
SCC : Links oshow chassis fabric sibs lcc (TX Matrix Router)
user@host> show chassis fabric sibs lcc 0
lcc1-re0:
--------------------------------------------------------------------------
Fabric management SIB state:
SIB #1
plane state: S_ACTIVE
FPC #0
PFE #0 : Links ok
FPC #2
PFE #1 : Links ok
FPC #4
PFE #0 : Links ok
FPC #5
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
SCC : Links ok
SIB #2
plane state: S_ACTIVE
FPC #0
PFE #0 : Links ok
FPC #2
PFE #1 : Links ok
FPC #4
PFE #0 : Links ok
FPC #5
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
SCC : Links ok
SIB #3
plane state: S_ACTIVE
FPC #0
PFE #0 : Links ok
FPC #2
PFE #1 : Links ok
FPC #4
PFE #0 : Links ok
FPC #5
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
SCC : Links ok
SIB #4
plane state: S_ACTIVE
FPC #0
PFE #0 : Links ok
FPC #2
PFE #1 : Links ok
FPC #4
PFE #0 : Links ok
FPC #5
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
SCC : Links ok show chassis fabric sibs scc (TX Matrix Router)
user@host> show chassis fabric sibs scc
scc-re0:
--------------------------------------------------------------------------
Fabric management SIB state:
SIB #1
plane state: S_ACTIVE
LCC #0 : Links ok
LCC #1 : Links ok
SIB #2
plane state: S_ACTIVE
LCC #0 : Links ok
LCC #1 : Links ok
SIB #3
plane state: S_ACTIVE
LCC #0 : Links ok
LCC #1 : Links ok
SIB #4
plane state: S_ACTIVE
LCC #0 : Links ok
LCC #1 : Links ok show chassis fabric sibs slot (PTX3000 Router)
user@host> show chassis fabric sibs slot 0
Fabric management SIB state:
SIB #0 Online
Fcore #0 (plane 0) Active
FPC #8
PFE #0 : OK
PFE #1 : OK
FPC #12
PFE #0 : OK
PFE #1 : OK
Fcore #1 (plane 1) Active
FPC #8
PFE #0 : OK
PFE #1 : OK
FPC #12
PFE #0 : OK
PFE #1 : OK show chassis fabric sibs slot (Junos OS Evolved PTX10008 and PTX10016)
The output of the show chassis fabric sibs command is modified
to include ASIC information. In the earlier releases, this command displayed
ASICs as FCOREs. With this modification, for every FPC and SIB, information
about ASIC and FCORE is presented separately in the output.
Each fabric
chip hosts 2 planes (plane 0, 1) in PTX10008. Each fabric chip hosts a single
plane (plane 0) in PTX10016.
PTX10008 supports 0-7 FPCs. PTX10016 supports 0-15 FPCs.
user@host> show chassis fabric sibs slot 0
Fabric management SIB state:
SIB #0 Online
Asic #0 Fcore #0 (plane 0) Empty
FPC #0
PFE #0 : Links ok
PFE #1 : Links ok
PFE #2 : Links ok
PFE #3 : Links okshow chassis fabric sibs (PTX10008 Router)
user@host> show chassis fabric sibs
Fabric management SIB state:
SIB #0 Online
FASIC #0 (plane 0) Active
FPC #0
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
FPC #5
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
FPC #6
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
FASIC #1 (plane 1) Active
FPC #0
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
FPC #5
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
FPC #6
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
SIB #1 Online
FASIC #0 (plane 2) Active
FPC #0
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
FPC #5
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
FPC #6
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
FASIC #1 (plane 3) Active
FPC #0
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
FPC #5
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
FPC #6
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
PFE #4 : OK
PFE #5 : OK
SIB #2 Empty
SIB #3 Empty
SIB #4 Empty
SIB #5 Empty
show chassis fabric sibs (QFX10008 Switch)
user@host> show chassis fabric sibs
Fabric management SIB state:
SIB #0 Online
FASIC #0 (plane 0) Active
FPC #0
PFE #0 : OK
PFE #1 : OK
PFE #2 : OK
PFE #3 : OK
FPC #1
PFE #0 : OK
PFE #1 : OK
FASIC #1 (plane 1) Active
FPC #0
PFE #0 : OK
PFE #1 : OK
FPC #12
PFE #0 : OK
PFE #1 : OK
SIB #1 Empty
SIB #2 Empty
SIB #3 Empty
SIB #4 Empty
SIB #5 Empty Release Information
Command introduced before Junos OS Release 7.4.
Command introduced on QFX Series switches in Junos OS Release 15.1X53-D30