Disabling Line Card Restart to Limit Recovery Actions from Degraded Fabric Conditions
You can disable line card restarts to limit recovery actions
from a degraded fabric condition. On T640 and T1600 routers, only
the fabric plane is restarted. On PTX Series routers, only the Switch
Interface Boards (SIBs) are restarted. To disable the restarting of
line cards, use the action-fpc-restart-disable
statement
at the [edit chassis fabric degraded]
hierarchy level:
[edit chassis fabric] degraded
Whenever a line card restart is disabled, an alarm is raised when there are unreachable destinations present in the router, and you must restart the line cards manually.
To ensure that both the fabric planes (T640 and T1600 routers)
or the SIBs (PTX Series routers) and the line cards are restarted
during the recovery process, do not configure the action-fpc-restart-disable
statement at the [edit chassis fabric degraded]
hierarchy
level.