watchdog (PSM)
Syntax
watchdog{ timeout value; pat-frequency value; }
Hierarchy Level
[edit chassis psm]
Description
Enable the power supply module (PSM) watchdog feature. Generally, Junos detects the thermal event health events and takes the required action as per user configuration. However, if a thermal health event causes Junos to go down, the PSM watchdog feature detects it and shuts down the router.
The PSM watchdog feature works only if all the online PSMs in the router support the feature.
Options
timeout value | Specify the watchdog timer in seconds. After the specified duration, the watchdog expires.
|
pat-frequency value | Specify the frequency (in minutes) at which the software resets the watchdog counter. If the watchdog counter doesn’t get reset because of reasons such as Routing Engine crash and system reboot, on watchdog timer expiry, the PSM turns off the output power.
|
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 20.1R1.