set chassis fpc

Syntax

Syntax (ACX7900 Devices)

Syntax (PTX10003 Devices)

Syntax (PTX10004, PTX10008, and PTX10016 Devices)

Description

(ACX7900 and PTX Series devices) Configure no VLAN tagging for a specific FPC. Additionally, configure power off configuration (PTX10003 devices only).

Options

fpc fpc_id

For PTX devices, fpc_id value is 0 to 15.

pfe pfe_id power (off | on)

Individual PFE Power off configuration option is available for ACX7900 and PTX10003 devices only. The reset-pfe error action is available for PFE power off and restart.

• Slot range for FPC is 0 to 1 for PTX10003-8T. Slot range for FPC is 0 to 3 for PTX10003-16T.

• PFE number range is 0 to 7 for all the FPCs.

• If no power configuration is present, then PFE is considered powered ON.

max-power <power>

Individual PFE maximum power configuration option is available for ACX7900 devices only. Configure maximum power for the FPC slot.

no-vlan-tagging

Individual PFE maximum power configuration option is available for PTX10003 devices only. Configure maximum power for the FPC slot.

no-temperature-monitoring

Disable temperature monitoring to explicitly disable optics temperature sensors for EM policy support, on specific WAN ports.

Usage

Use delete chassis fpc no-vlan-tagging command to disable no-vlan-tagging.

Required Privilege Level

maintenance

set chassis fpc (PTX)

Release Information

Command introduced in Junos OS Release 21.3R1.

power-off option introduced for PTX10003 devices in Junos OS Evolved Release 22.4R1.